BusWorks
®
900EN-S005 Ethernet Switch User’s Manual Ethernet I/O
__________________________________________________________________
_______________________________________________________________________________________
Acromag, Inc. Tel:248-624-1541 Fax:248-624-9234 Email:
http://www.acromag.com
34
REG
DESCRIPTION
DEF
24
18H
Port 1 Control 8
00H
Bit
Function
7-0
Receive HIGH Priority Rate Control [7:0]:
This byte along with Port Control 10 bits [3:0] form
a 12-bit field to determine how many “32Kbps” high
priority blocks can be received (in a unit of 32K bits
or 4K bytes in a one second period).
0
40
28H
Port 2 Control 8 -
See Port 1 Control 8 Description.
00H
56
38H
Port 3 Control 8 -
See Port 1 Control 8 Description.
00H
72
48H
Port 4 Control 8 -
See Port 1 Control 8 Description.
00H
88
58H
Port 5 Control 8 -
See Port 1 Control 8 Description.
00H
25
19H
Port 1 Control 9
00H
Bit
Function
7-0
Receive LOW Priority rate Control [7:0]:
This byte along with Port Control 10 bits [7:4] form
a 12-bit field to determine how many “32Kbps” low
priority blocks can be received (in a unit of 32K bits
or 4K bytes in a one second period).
0
41
29H
Port 2 Control 9
-See Port 1 Control 9 Description.
00H
57
39H
Port 3 Control 9 -
See Port 1 Control 9 Description.
00H
73
49H
Port 4 Control 9 -
See Port 1 Control 9 Description.
00H
89
59H
Port 5 Control 9 -
See Port 1 Control 9 Description.
00H
26
1AH
Port 1 Control 10
00H
Bit
Function
7-4
Receive LOW Priority Rate Control [11:8]: This
nibble along with Port Control 9 bits [7:0] form a 12-
bit field to determine how many “32Kbps” low
priority blocks can be received (in a unit of 32K bits
or 4K bytes in a one second period).
0000
3-0
Receive HIGH Priority Rate Control [11:8]: This
nibble along with Port Control 8 bits [7:0] form a 12-
bit field to determine how many “32Kbps” high
priority blocks can be received (in a unit of 32K bits
or 4K bytes in a one second period).
0000
42
2AH
Port 2 Control 10
–Port 1 Control 10 Description.
00H
58
3AH
Port 3 Control 10
-Port 1 Control 10 Description.
00H
74
4AH
Port 4 Control 10
-Port 1 Control 10 Description.
00H
90
5AH
Port 5 Control 10
-Port 1 Control 10 Description.
00H
Register Map