BusWorks
®
900EN-S005 Ethernet Switch User’s Manual Ethernet I/O
__________________________________________________________________
_______________________________________________________________________________________
Acromag, Inc. Tel:248-624-1541 Fax:248-624-9234 Email:
http://www.acromag.com
64
4
ON
1
2
3
4
2
1
5
4
8
7
9
1
5
6
ON
10
25
3
6
BROWN
TO X3-2
P1 SOCKET
PIN NUMBERS
2
TO X3
TO X3-1
(GROUND)
TO X3-5
BLUE
DB25M
16
TO X3-4
1
DB25-9 (YELLOW)
GREEN
TO X3-6
NOTE: P1 IS
KEYED VIA PIN 3
DB25-25 (BROWN)
DB25-16 (GREEN)
P1 SOCKET
BROWN
BLUE
DB25-1 (BLUE)
DB25-10 (RED)
CABLE MODEL 5035-365
TO PC PARALLEL PORT
RED
NOTE: PIN 3 IS CUT
P1 IS USED TO OPTIONALLY
PROGRAM THE SWITCH
EEPROM REGISTERS, OR TO
UTILIZE SPI RUNTIME MODE.
LENGTH <= 50 INCHES
COLOR-CODED
IDC RIBBON CABLE:
BLUE
GREEN
YELLOW
ORANGE
RED
BROWN
FOR EEPROM PROGRAMMING
AND/OR SPI RUNTIME MODE
COMPLETED CABLE IS MODEL 5035-365.
PROGRAM INTERFACE KEY (P1)
YELLOW
900EN-S005 TOP EDGE
CABLE AND HEADER ASSEMBLY IS ACROMAG PART 1004-929.
HEADER & DB25 PINS (WIRE COLOR)
DB25M IDC CONNECTOR IS ACROMAG PART 1004-930.
NOTE: ORANGE IS
NOT CONNECTED.
For very noisy environments or in the presence of strong electrical fields, you
can obtain double-shielded CAT-5e cable and shielded RJ45 plugs from the
following vendors:
•
L-com Connectivity Products,
www.L-com.com
, see cable model
TFSC2004 and shielded plug T8P8CSR.
•
Regal
Electronics,
www.regalusa.com
, see shielded plug model
1003B-8P8CSR-C5.
Complete premium double-shielded Category 5e standard and crossover
cables in variable lengths can be obtained from Lumberg at
www.lumbergusa.com
(refer to their etherMate line). For example, specify
RJ45S-RJ45S-656/B/3M for a double-shielded, 3 meter straight cable.
Specify RJ45S-RJ45S-656/BX/3M for a double-shielded, 3 meter crossover
cable.
This module has many advanced programmable features. If you wish to
take advantage of these features, you will need to purchase the following
programming cable from Acromag:
Cable Model 5035-365
– A 4 foot long, 6-wire IDC cable with a 6-pin header
at one end (2 rows of 3 pins with pin 3 removed) and a DB25M connector at
the other end. This cable is used to connect between the parallel port of a
personal computer and the program port of the 900EN-S005. Use this cable
to write to EEPROM of the switch (EEPROM Mode), or to access the
runtime registers of the switch in SPI Slave Mode. Additional software is
required to use this cable and is located on the CDROM shipped with your
unit. A diagram of this cable and interface is provided below.
If you need to service this cable, or you wish to build your own cable, you
can obtain the necessary parts from other vendors. For the 6-wire IDC cable
and header assembly, see Samtec part number HCMD-03-S-50.00-02
(
www.samtec.com
). The DB25M IDC connector is a common part that can
be obtained from many vendors including 3M (
www.3M.com
), and Kycon
(
www.kycon.com
).
Patch Cable &
Crossover Cable
Programming Cable
5035-365