Technical Data
G20
G20/G25
G25/G25.3
G20/G25
I2H,I2E
I2E+
I2L/ I2EK
I2ELL
Gas type
I2(43.46 -45.3 MJ/m3
(0°C))
Supply Pressure
mbar
20
20 / 25
25
20
Nominal Heat Input Gross (Hs) kW
9.1
9.1 / 8.4
8.5
7.5
Nominal Heat Input Ne
�
(Hi)
kW
8.2
8.2 / 7.6
7.7
6.8
Consump
�
on
m³/hr
0.84
0.840 /
0.905
0.89
0.8
Burner Pressure (hot)
mbar
13.2
13.2 / 16.4
16.6
13.4
Injector Marking
120 Centre, 260 Le
�
, 260 Right
Pilot
G30-ZP2-312 (31.2 inj)
E
ffi
ciency Class
1
Nox Class
5
Type
C11 / C31
G30/G31
G30/G31
G31
G31
G31
Gas type
I3B/P(30)
I3+
I3P(50)
I3P(37)
I3P(30)
Supply Pressure
mbar
30
30 / 37
50
37
30
Nominal Heat Input Gross (Hs) kW
8
8
8
8
7
Nominal Heat Input Ne
�
(Hi)
kW
7.4
7.4
7.4
7.4
6.5
Consump
�
on
m³/hr
0.225
0.225 / 0.29
0.29
0.29
0.253
Burner Pressure (hot)
mbar
27
27 / 36
36
36
28
Injector Marking
80 Centre, 100 Le
�
, 100 Right
Pilot
G30-ZP2-271 (27.1 inj)
E
ffi
ciency Class
1
Nox Class
5
Type
C11 / C31
This product has been tested and cer
�fi
ed for use on Biopropane Gas.
Biopropane Gas can be used as a fuel, with no adjustment necessary if the product is
installed as an LPG version.
42
Summary of Contents for NEO Electric
Page 42: ...Technical Informa on 41...
Page 44: ...Dimensions NEO3FGAS NEO3PGAS NEO3CGAS NEO3WGAS 43...
Page 49: ...48...