4. Place the control box into the holder located on the underside back le

 of the appliance ensuring 

that the wiring is not trapped in any way.  

 

7. The appliance is now ready to be connected to the gas supply pipework and the 

ue connec

on 

can be made. 
 

 

5.Replace the perforated grate.

 

6. Place the elevated burner ports onto the le

 and right gas outlets as shown. The 

le

- hand elevated port should sit in the 6

th

 groove from the front. The right-hand 

elevated port should sit in the 3

rd

 groove from the front. Make sure that both ports 

are securely located on the outlet ports. 
 

 

18

Summary of Contents for NEO Electric

Page 1: ...er ed for other coun es see technical data However to install appliance in other countries modi ca on of the appliance and its method of installa on may be necessary in order to use the appliance safe...

Page 2: ...11 Manual User Instruc ons Page 12 Cleaning Maintenance Page 13 Installa on Instruc ons Page 15 Clearance Requirements Page 16 Installa on of Appliance Page 17 Burner Installa on Page 19 Flue Connec o...

Page 3: ...sence of local codes in accordance with the Na onal Fuel Gas Code ANSI Z223 1 NFPA 54 or the IFGC or CSA B149 1 All piping and tubing must comply with local codes andordinances Use only your hand to p...

Page 4: ...rbon monoxide detector conforming to EN50291 is permanently xed in the same room as the appliance Opera ng the Appliance for the First Time Before igni ng the appliance ensure that all packaging safet...

Page 5: ...do NOT use metal tools to remove the ba eries from the handset Receiver Withoutusingamainsadapter ba ery replacementisrecom mended at the beginning of each hea ng season Old or dead ba eries should be...

Page 6: ...ram Mode Thermosta c Mode also deac vates Program Mode Eco Mode Light Dimmer Opera on Circula ng Fan Opera on 2nd Burner Feature Countdown Timer Install ba eries All icons are displayed and ashing Whi...

Page 7: ...e Time Press and bu ons simultaneously Day ashes Press or bu on to select a number to correspond with the day of the week Monday 1 Tuesday 2 Wednesday 3 Thursday 4 Friday 5 Saturday 6 Sunday 7 Press a...

Page 8: ...cally goes into Manual Mode a er main burner ignition Standby Mode Pilot Flame Handset Pressandhold bu on to set appliance to pilot ame To Turn OFF Fire Press bu on to turn o NOTE A new igni on is po...

Page 9: ...bu on to enterManual Mode Press bu on to enter Thermosta c Mode Press bu on to enter Program Mode Program Mode ON Press Program Bu on Program 1 or 2 ON or OFF is displayed OFF Press Program bu on Pre...

Page 10: ...u on to choose between ALL SA SU 1 2 3 4 5 6 7 Press the program bu on to con rm ALL selected ON TIME SETTING PROGRAM 1 Program ON 1 is displayed ALL is displayed shortly HOUR ashes Toselect hour pres...

Page 11: ...he week for mul ple day of the week or for everyday of the week Wait to nish se ng 2nd Burner Feature The latching solenoid valve will open automa cally a er igni on or a er switching the system OFF s...

Page 12: ...s pilot to the manually ignited and prevents main gas flow Manual knob ON Allows automatic ignition Manual Turn O In the event that the appliance needs to be turned OFF manually for instance if the re...

Page 13: ...sed for some me This can be done with a so brush and a vacuum cleaner or a damp cloth and if required a non abrasive cleaning agent Do not use corrosive or abrasive substances to clean the exterior of...

Page 14: ...e burnt into the glass and will be un removable Do not operate this appliance if the glass panel has been broken or cracked removed or is open The appliance is designed to t numerous installa on situa...

Page 15: ...regula ons This appliance is intended for use on a gas installa on with a governed meter Appliance Fireplace Installa on Determine the posi on required for the appliance Create a gas connec on for the...

Page 16: ...ial If the appliance is to be installed in a non combustible opening these clearances can be reduced but the clearance for the rear must always be 50mm minimum You must ensure that if reducing the cle...

Page 17: ...needs to be taken The appliance is able to be installed with a rear ue op on when used in conjunc on with the ACR snorkel kit to prepare the appliance for this applica on the ue collar assembly will n...

Page 18: ...at the exible gas supply pipe is not damaged in any way and that it s protruding from the rear of the appliance or if desired from the removeable plate located in the pedestal 2 Lift out the perforate...

Page 19: ...ed to the gas supply pipework and the ue connec on can be made 5 Replace the perforated grate 6 Place the elevated burner ports onto the le and right gas outlets as shown The le hand elevated port sho...

Page 20: ...n the UK Car Port or Building Extension Where a ue terminal is sited within a car port or building extension it should have at least two completely open and unobstructed sides The distance between the...

Page 21: ...cent to an opening air brick opening window etc 400 D Below gutters soil pipes or drain pipes 300 E Below eaves 300 F Below balconies of car port roof 600 G From a ver cal drain pipe or soil pipe 300...

Page 22: ...Rise 4 6m 50mm Restrictor Ver cal Rise 6 9m 35mm Restrictor Ver cal Rise 9m No Restrictor Horizontal Wall Vent Termina on Flue sizing Neo 100 150 Connector on appliance 100 150 Maybe used throughout...

Page 23: ...elow con gura on is adhered to at all mes The Snorkel Terminal GFK2 ACR REAR SNORKEL KIT MUST always be installed inline with manufacturers instruc ons and a maximum horizontal length of 500mm before...

Page 24: ...Examples of possible alterna ve ueing arrangements Contact your local dealer for more informa on 23...

Page 25: ...Examples of possible alterna ve ueing arrangements Contact your local dealer for more informa on 24...

Page 26: ...Examples of possible alterna ve ueing arrangements Contact your local dealer for more informa on 25...

Page 27: ...Examples of possible alterna ve ueing arrangements Contact your local dealer for more informa on 26...

Page 28: ...Log Layout This kit will contain Crystals Crystals are only available with LED light options Bark Effect Fireglow Fibres 8 Realistic Hard Ceramic Logs 2 Elevated Burner Ports 27...

Page 29: ...where the gas will be released from enter into the stove chamber Step 2 Once the Elevated Burner Ports are in place If you have asked for the LED op on in your gas stove place the crystals accordingly...

Page 30: ...situated under the Elevated Burner Ports in a central posi on Step 5 Place Log 2 into the chamber This needs to be placed to the back of the stove to the rear of Log 1 Step 6 Place Log 3 on top of the...

Page 31: ...p of the Right Elevated Burner Port The scorched looking side of the bark facing the front Step 8 Place Log 5 below the 2 Burner Ports that are now hidden by logs 3 4 Step 9 Place Log 6 in between log...

Page 32: ...by Step Step 10 Place Log 7 on top of log 5 The scorched end of the log touching the middle of log 5 Step 11 Place Log 8 on top of log 5 in front of log 7 The scorched end of the log should be facing...

Page 33: ...the pilot light as described in the User Instruc ons 2 Turn on the main burner as described in the User Instruc ons 3 Check that the pilot smoothly cross lights to the main burner and that the main b...

Page 34: ...9 The measured value should be within 10 of the described value If this is not the case please contact the supplier Note A er checking the pressures and removing the manometers the screws in the Pres...

Page 35: ...s of combus on is disturbed If the appliance repeatedly shuts o a er being restarted as detailed in the Ligh ng instruc ons sec on a GAS SAFE registered engineer should be contacted to examine the app...

Page 36: ...del No Stove Serial No Burner Serial No Gas Type Installation Company Gas Safe Registered Engineer Contact No Gas Safe Register No Date of Installation Gas Checklist Pass Fail Gas Tightness Test Stand...

Page 37: ...ht and pins are straight 2 Latching Solenoid Replace Latching Solenoid 3 Receiver Replace Receiver and reprogram code 4 Handset Check that the Handset shows the AUX symbol if you press SET UP ISSUE PO...

Page 38: ...3 Receiver Replace Receiver and reprogram code see OBSERVED PROBLEM C REMEDY to POSSIBLE CAUSE 2 4 Bent pins on 8 Wire Connector see gures 7 and 9 Straighten pins on 8 Wire Connector 5 Valve Replace V...

Page 39: ...two addi onal short beeps con rming the new code is set 3 The Receiver is surrounded by metal reducing the transmission range Change the posi on of the adjustable antenna ISSUE POSSIBLE CAUSE SOLVE Co...

Page 40: ...approximately 60 seconds see gure 9 1 Not enough voltage generated from the Thermocouple or too much resistance in the circuit NOTE To nd which part of the circuit is causing the problem a checklist f...

Page 41: ...ural G30 ZP2 312 3 Pilot Assembly LPG G30 ZP2 271 4 Pilot Assembly Gasket G30PSZPS2 5 Flexible Tube 8 x 300mm s s IGO8030 6 Latching Solenoid GV S60C 12 Front Window Panel Not Shown N41045001 Ceramic...

Page 42: ...Technical Informa on 41...

Page 43: ...ass 1 Nox Class 5 Type C11 C31 G30 G31 G30 G31 G31 G31 G31 Gas type I3B P 30 I3 I3P 50 I3P 37 I3P 30 Supply Pressure mbar 30 30 37 50 37 30 Nominal Heat Input Gross Hs kW 8 8 8 8 7 Nominal Heat Input...

Page 44: ...Dimensions NEO3FGAS NEO3PGAS NEO3CGAS NEO3WGAS 43...

Page 45: ...e under side of the pilot can be un done using a 10mm spanner where appropriate To access the main burner injectors the burner base units must be removed This is done by removing the four bolts M6 10m...

Page 46: ...s Safe Register No Gas Safe Register No Date of Service Date of Service Door Seal replaced Door Seal replaced Annual Service Record Year 3 Annual Service Record Year 4 Gas Safe Registered Engineer Gas...

Page 47: ...s Safe Register No Gas Safe Register No Date of Service Date of Service Door Seal replaced Door Seal replaced Annual Service Record Year 7 Annual Service Record Year 8 Gas Safe Registered Engineer Gas...

Page 48: ...nly a 12 month warranty will be applicable as outlined below All stoves are covered by a 1 year warranty when purchased through a non recommended retailer The warranty covers the stove body cas ngs on...

Page 49: ...48...

Page 50: ...ACR Heat Products Unit 1 Weston Works Weston Lane Birmingham West Midlands UK B11 3RP Tel 0121 706 8266 Website www acrheatproducts com Email enquiries acrheatproducts co uk...

Reviews: