9
Maintenance
The chimney should be swept at least once a year together with the flue
pipe connection. Care should be taken to ensure that there is not a build
up of soot on the baffle and in the airways of the appliance.
If the appliance has not been operated for long periods, the flue should be
inspected and swept before use to ensure there are no blockages within
the flue.
The grate should be cleaned regularly and the ashpan emptied daily.
NEVER ALLOW THE ASH IN THE ASHPAN TO OVERFILL ALLOWING ASH TO BE IN
CONTACT WITH THE UNDERSIDE OF THE GRATE
. This will overheat the grate
and cause premature wear and distortion.
The internal vermiculite panels of the appliance should be checked
regularly for soundness. If any wear and tear is found, we recommend
these parts are replaced immediately.
Check the rope door seals are intact and are not worn. These should be
replaced on an annual basis to ensure the correct operation of this
appliance.
The glass can be cleaned using a soft damp cloth or ACR Glassbright
ceramic glass cleaner (available from your local ACR Stove stockist)
Use only replacement parts recommended by the manufacturer.
We recommend that the appliance is serviced annually by a competent
engineer to ensure its continued safe operation.