8
Assembly of the unit
This appliance is equipped with a manufactures smoke exempt stop
Pre – fitted, under no circumstances should it be tampered with or removed
unless expressly authorized by a competent person
The appliance is supplied pre-assembled with the flue spigot in the top exit
position.
If you intend to install the appliance using a rear flue connection, the
blanking plate should be swapped over as follows:
Remove the internal baffle plate.
Remove the rear blanking plate.
Remove the flue spigot from the top exit by removing the securing bolts
and rope seal.
Refit the rope seal and flue spigot to the rear exit and secure with the
bolts.
Refit the blanking plate to the top exit using the rope seal and retaining
bolts.