3
MALVERN SPECIFICATIONS
Nominal heat output ………… 5 kW – WOOD 4.8 kW – SMOKELESS FUEL
Chimney draft required ……… 12Pa
Height …………………………… 535 mm
Width ……………………………. 445 mm
Depth ………………………….... 285 mm
Weight …………………………… 80 kg
Air Requirement ……………….. N/A ***
Flue Mass Gas Flow …………… 4.3g/s – WOOD 7.1g/s – SMOKELESS FUEL
Mean Flue Gas Temperature... 273°C – WOOD 273°C - SMOKELESS FUEL
Efficiency ………………………... 78.3% - WOOD 70.8% - SMOKELESS FUEL
Log Length ………………………. Up To 350 mm
*** Please note that Building Regulations Document J advises that
additional permanent air supply is required for appliances with an output of
above 5Kw.
With modern properties additional air may be required as Document J
suggests that adequate air would be a benefit.
If design air permeability ≥5.0m³/ (h.m²) then 550mm²/kW of appliance
rated output above 5kW
Or
If design air permeability ≤5.0m³/ (h.m²) then 550mm²/kW of appliance
rated output
If in doubt, please consult your registered installer for advice.
NOTE: DO NOT INSTALL IN A ROOM CONTAINING AN EXTRACTOR FAN
Summary of Contents for MV2CL
Page 4: ...4 MV2CL Dimensions ...
Page 16: ...16 Malvern Classic Exploded Diagrams ...
Page 17: ...17 ...
Page 18: ...18 ...