background image

Y1-03-0138U

 

23 

 
 
 
 
 

 

EC DECLARATION OF CONFORMITY 

ACR  Electronics,  Inc.  hereby  declares  that  the  following  product  is  in  conformity  with 
Directive 2004/108/EC of the European Parliament and of the Council of 15 December 
2004 on Electromagnetic Compatibility (EMC Directive). In accordance with the Directive, 
the product will be marked with the CE conformity marking as follows: 

 

Product:  

Searchlight 

 

 

Model: RCL-100D 

Regulations and 

EN 60945:2002: Emissions

 

Standards:

 

CISPR 16-1:1999 (Conducted Emissions) 

 

 

CISPR 16-1:1999 (Radiated Emissions) 

EN60945: 2002: Immunity: 

IEC 61000-4-2: 1995 (Electrostatic Discharge) 
IEC 61000-4-3: 1995 (Radiated Immunity) 
IEC 61000-4-4: 1995 (Immunity to Fast Transients) 
IEC 61000-4-6: 1995 (Conducted Immunity, Power and I/O Leads) 
IEC 61000-4-11: 1994 (Voltage Dips and Interrupts) 

Manufacturer:  

ACR Electronics Inc.  

European 

ACR Electronics Inc.

 

 

5757 Ravenswood Road 

Representative:  

(European Office) 

 

Fort Lauderdale, FL 33312 

1 Rose Cottages, Pitmore Lane, 

 

USA 

Sway, Lymington, Hampshire 

 

SO41 6BX UK 

 

Signed on behalf of ACR Electronics Inc. 

 

Signed: 

__________________________________________ 

 

Name:  Thomas Pack 

 

Date: 

November 1, 2010 

Title: 

Director - New Product Development 

 

 
 

Document RCL-100D-003 

 

 

 

 

This Declaration complies with 

ISO/IEC 17050-1:2004 

 
 
 

ACR Electronics, Inc. is registered by UL to ISO 9001:2000

 

Summary of Contents for RCL-100D

Page 1: ...Y1 03 0138U i PRODUCT SUPPORT MANUAL RCL 100D Remote Control Searchlight System Model No RCL 100D Product No 1930 3 1931 3 Y1 03 0138 Rev U ...

Page 2: ...URP 102 POINT PAD ___________________ 5 SECTION 6 URC 102 MASTER CONTROLLER __________ 10 APPENDIX A RCL 100D SPECIFICATIONS _____________ 16 APPENDIX B USER REPLACEABLE PARTS _____________ 17 APPENDIX C BULB REPLACEMENT PROCEDURE _______ 18 APPENDIX D PRODUCT COMPONENTS ______________ 19 APPENDIX E ACCESSORY COMPONENTS _____________ 20 APPENDIX F WARRANTY NOTICES _________________ 22 PLEASE READ ...

Page 3: ... quality raw materials and quality controlled manufacturing produce a superior product The Test Facility at ACR can reproduce some of the harshest environmental conditions known to man This assures that the products we produce can stand up to the tough marine environment With proper care and maintenance your searchlight will be in service for years to come ACR is proud to be ISO 9001 certified the...

Page 4: ...ght body makes it attractive for recreational and commercial vessels The Searchlight is totally enclosed and is made of rugged aluminum alloy It is gasketed and finished to be resistant to the weather Mounting Make sure the area is clean and dry The Searchlight can be mounted where desired using appropriate length 3 16 diameter stainless steel fasteners Four 4 nylon shoulder washers are supplied w...

Page 5: ...side of the mounting location Make sure there are no obstructions behind the area where the switch is to be located e g bulkheads wires plumbing or hardware Check in advance that the coax cable from the Master Controller can be routed to this location Generally the Point Pad should be mounted in a protected area Install the surface mount Point Pad by drilling 3 holes in the dashboard location usin...

Page 6: ...r through ACR Electronics your local Radio Shack or other sources of electronic hardware Additional Point Pads up to three 3 Pads may be used with one 1 Master Controller A standard T connector or RG 59 television type splitter is used for each additional Point Pad see Figure 2 Limit the total length of all coax cable used to 300 feet The URP 102 Point Pad is backwards compatible with all RCL 100 ...

Page 7: ...Pad URP 102 Point Pad URP 102 Point Pad URC 102 Master Controller Unit URC 102 Master Controller Unit Power Source Power Source RG 59 Coaxial Cable RG 59 Coaxial Cable RG 59 Coaxial Cable RG 59 Coaxial Cable Fuse Fuse T Conn or Splitter Single Point Pad Multiple Point Pads ...

Page 8: ...Arrows to raise or lower the Searchlight beam To activate the XRCiZ feature press and hold the ON OFF button for greater than 5 seconds The green LED indicates XRCiZ feature is enabled To deactivate the XRCiZ feature Press and hold the ON OFF button for greater than 5 seconds The red LED indicates XRCiZ feature is disabled An LED blinking red green indicates that the XRCiZ feature is now exercisin...

Page 9: ...Y1 03 0138U 9 Figure 4 URP 102 Point Pad Surface Mount Case Figure 5 URP 102 Point Pad Flush Mount Case ...

Page 10: ... routed to this location Mount the Master controller with the wires and coax facing down Use an appropriate fastener for your mounting location Use a sealant in fastener holes to prevent moisture intrusion General Wiring Scheme The RCL 100 has a unique wiring scheme Special attention must be paid to the following chart The Master Controller is supplied with an in line fuse holder on the Orange pow...

Page 11: ...attached to the end of the 15 Searchlight wire harness If you must lengthen the wire harness use heavy duty wire to minimize the voltage drop This is especially important for the YELLOW lamp power and GREEN lamp ground wires Following the wiring scheme shown in Table 1 use the supplied butt connectors to connect the Master Controller to the Searchlight Wiring to Point Pad The RG 59 Coax cable is s...

Page 12: ...ure The XRCiZ feature routinely operates all moving parts in the Searchlight to keep the motors and drive mechanism freely running Once activated and every 30 days thereafter the XRCiZ feature wakes up and operates the Searchlight The Searchlight will rotate 360 in both directions and the parabolic reflectors will move to the full up and down positions This feature keeps the Searchlight in peak wo...

Page 13: ...brightest searchlight performance and long bulb life Also to extend lamp life the Master Controller has a timed lamp power up feature The searchlight lamps reach full intensity within 2 seconds The URC 102 Master Controller has a searchlight motor timeout feature If a Point Pad rotation switch right or left is continuously engaged for more than 50 seconds the Master Controller will interrupt the o...

Page 14: ...Point Pads 75 ohm TV Coaxial Cable 75 ohm TV Coaxial Cable T Connector or Optional 75 Ohm Splitter for Multiple RCL 100 Point Pads Ground Blue Orange Note Wiring must be in accordance with this diagram Improper wiring will damage components 12 VDC or 24 VDC Master Controller in line 15 amp fuse Power Source Fuse Figure 7 URC 102 Master Controller Wiring Diagram ...

Page 15: ...Y1 03 0138U 15 Figure 8 URC 102 Master Controller ...

Page 16: ...55WDX 70W halogen Lamp X2 base G6 35 JDC24V 55WDX Peak beam candle power candela 200 000 160 000 Beam spread degrees Horizontal 7 Vertical 5 Horizontal 7 Vertical 5 Elevation angle degrees Up 9 Down 17 Up 9 Down 17 Turning angle degrees 360 360 Elevation speed 4 per second 6 per second Turning speed Fast 28 per second Slow 15 per second Fast 28 per second Slow 15 per second Weight 7 15lbs 3 24 kg ...

Page 17: ...ame 1 HRMK 2101 3A Window Weather Strip 1 HRMK 1201 3B Screw M4x18 2 HRMK 1600 3C Washer M408 2 HRMK 9301 4 Gasket of front frame 1 HRMK 2200 5 10 cm reflector 2 HRMK 1301 6 Protection Cover 1 HRMK 2102 7 O Ring 594 1 HRMK 2202 8A 55W quartz halogen bulb 12V 2 6001 8B 55W quartz halogen bulb 24V 2 6003 9 Shoulder Washer 4 A1 05 0660 24 10 Base Housing 1 HRMK 2103 11 Head Housing 1 HRMK 2100 ...

Page 18: ...lbs to cool 2 Remove two screws holding the front flange and glass in place 3 To remove the old lamp bulbs grasp base of the lamp and pull straight out WARNING Do not touch glass parabolic reflector with fingers or tools 4 Install the new lamp bulb using a soft clean cloth to avoid touching the bulb with your fingers Insert the lamp bulb pins into socket and press firmly in place CAUTION If the la...

Page 19: ... 0776 Washers 2 A1 05 0777 Warranty Card 1 A1 20 1019 Product Support Manual 1 Y1 03 0138 Mounting Templates 1 Y1 03 0138 1 Product No 1931 3 RCL 100D 24 V Searchlight Installation Kit includes Description Quantity ACR Part Number Searchlight RCL 100D 24 V 1 A3 06 1106 4 Kit Nylon Washers 4 1 A3 06 1940 Connector F 2 A1 03 0220 Cable Coaxial 15ft A2 07 0002 6 Master Controller URC 102 1 A3 06 2231...

Page 20: ...R Part Number Point Pad URP 102 with Surface Mount Case 1 A3 06 2230 Case Flush Mount 1 A1 18 1875 2 Gasket Surface Mount 1 A1 25 0140 1 Gasket Flush Mount 1 A1 25 0140 2 U Clamp 2 A1 17 1366 Nuts Nylon lock 2 A1 05 0776 Washers 2 A1 05 0777 Adapter Plate Flush mount 1 A1 18 1871 Adapter Plate Surface mount 1 A1 18 1892 Instruction Sheet Point Pad 1 Y1 06 0179 Mounting Templates 1 Y1 03 0138 1 Pro...

Page 21: ... 4 A1 03 0220 Instruction Sheet Point Pad 1 Y1 06 0179 Mounting Templates 1 Y1 03 0138 1 Product No 9283 3 Remote Control Installation Kit Includes Description Quantity ACR Part Number Master Controller URC 102 1 A3 06 2231 Connector In Line 8 A1 03 0222 Point Pad URP 102 with Surface Mount Case 1 A3 06 2230 Case Flush Mount 1 A1 18 1875 2 Gasket Surface Mount 1 A1 25 0140 1 Gasket Flush Mount 1 A...

Page 22: ...IND EXPRESS OR IMPLIED AS TO MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR ANY OTHER MATTER WITH RESPECT TO THIS PRODUCT The Company shall not be liable for consequential or special damages To place the warranty in effect register online at www acrelectronics com or return the attached card within 10 days Five years for the following products EPIRB PLB S VDR SSAS Notices ACR Electronics dili...

Page 23: ...ty IEC 61000 4 2 1995 Electrostatic Discharge IEC 61000 4 3 1995 Radiated Immunity IEC 61000 4 4 1995 Immunity to Fast Transients IEC 61000 4 6 1995 Conducted Immunity Power and I O Leads IEC 61000 4 11 1994 Voltage Dips and Interrupts Manufacturer ACR Electronics Inc European ACR Electronics Inc 5757 Ravenswood Road Representative European Office Fort Lauderdale FL 33312 1 Rose Cottages Pitmore L...

Reviews: