![ACPro AC Pro C Series Installation Instructions Manual Download Page 68](http://html1.mh-extra.com/html/acpro/ac-pro-c-series/ac-pro-c-series_installation-instructions-manual_2840709068.webp)
68
Technical Information
Replace the outdoor mainboard
YES
F3 Malfunction of Outdoor Ambient Temperature Sensor
F4 Malfunction of Discharge Temperature Sensor
Disconnect the temperature
sensor and measure if its resistance
is normal
Malfunction of discharge
temperature sensor
Correctly insert the
temperature sensor on
the needle stand
Replace the
temperature sensor
Check if the discharge
temperature sensor on mainboard
is inserted on the needle stand
correctly
YES
NO
NO
Replace the outdoor mainboard
YES
Disconnect the temperature sensor
and measure if its resistance is
normal
Malfunction of outdoor ambient
temperature sensor
Correctly insert the
temperature sensor on
the needle stand
Replace the
temperature sensor
Check if the outdoor ambient
temperature sensor on mainboard
is inserted on the needle stand
correctly
YES
NO
NO