Figure 44: UC-53A Thermal Response
7.7.4 Humidity Characteristics
The humidity characteristics of a microphone indicate how sensitivity changes at various humidity levels.
Figure 45 shows the humidity characteristics for a UC-53A microphone at 250Hz.
Figure 45: UC-53A Humidity Response
7.7.5 Reduction of Wind Noise by Windscreen
During outdoor measurements wind noise can falsify measurement results. To counter such problems, the recom-
mended windscreen WS-10 should be mounted on the microphone. The characteristics of the WS-10 windscreen are
shown below. The attenuation of wind noise produced by the windscreen is about 25dB with frequency weighting A
and 15dB with frequency weighting C.