23
If the amplifier CAT port is connected either to the transceiver BCD Band Data or Band Voltage output,
select the respective interface type and push EXIT. The other items and values will not be taken into
account
.
If the CAT cable is plugged into the transceiver’s serial port, select the interface and command set
according to Table 5-1. The baud rate has to be set to the same value as the transceiver’s. The byte
spacing and polling time may be left unchanged.
Last select the interface type (RS232 or TTL) according to the table 5-1 and used connection and
push EXIT.
Fig. 5-3 Menu “Selection of CAT/AUX interface” – CAT/AUX SETTINGS
Table 5-1
TRANSCEIVER
INTERFACE
COMM
SET
ELECRAFT
RS232
5
ICOM (Connection to the REMOTE jack)
TTL
1
ICOM (Connection to the RS232 port or CT17)
RS232
1
KENWOOD TS-2000, 480, 590, 890, 990 and similar
RS232
5
YAESU FT-101, 450, 950, 991, 1200, 2000, 3000,
5000, 9000 and similar
RS232
2
YAESU FT-1000MP
RS232
4
YAESU FT-817, 857, 897
TTL
3
Summary of Contents for 700S