22
22
Any value can be selected in each screen half. Using buttons ITEM1 and ITEM2 (up and down) select
the desired values. The two slected values will be shown continuously on the basic screen (S.3-2 (b),
Fig. 3-2) - after leaving this menu (EXIT button).
5-2. Menu “Amplifier service functions” – AMP SERVICE.
The amplifier service menu (Fig. 5-2) is accessible from the MENU SELECTION screen (Fig. 5) at RX
mode only.
C A U T I O N
The AMP SERVICE menu is used for checking and adjustment
of the zero-signal (idle) drain current of the final transistors and
for testing some functions and circuits of the amplifier when
serviced. We recommend these procedures are carried out only
by a trained service technician!
The necessary service function is selected with the ITEM buttons (up and down). With the SELECT
buttons (left or right) the selected function is turned ON or OFF.
The inactive functions are greyed out and the active are red. When leaving a function submenu, it is
turned off and deactivated automatically. At pressing the EXIT button all service functions are turned off,
and the MENU SELECTION screen comes back (Fig. 5). At consecutive pushing of the EXIT button, the
basic screen returns (Fig. 3-2).
Fig. 5.2 Menu “Service functions in the amplifier” – AMP SERVICE
5-3. CAT SETTINGS MENU
After a CAT cable is connected to both the transceiver and amplifier, the correct settings for the
transceiver have to be entered via this menu. If there is no CAT connection, OFF has to be selected as
Interface type.
The CAT settings are accessible only in RX mode – Fig. 5 and 5-3. The item is selected by the ITEM
buttons (up and down). The value is set with the SELECT buttons (left or right).
Summary of Contents for 700S