Operating Instructions DMMS_DIGISYS
ACO A
utomation
Co
mponents
44
PC-software DMMS/DIGISYS
Select measuring mode
Select one of the following measuring modes in the selection window:
No measurement
Measuring channel is deactivated
1 sensor MW batch
Batch measurement
Mean value calculator featur-
ing start-stop control and
delayed time
1 sensor
2 sensors MW batch
2 sensors which are summarised
3 sensors MW batch
3 sensors which are summarised
1 sensor MW continuous
Continuous measuring with
signal stabilisation
(continuous time)
1 sensor
2 sensors MW continuous
2 sensors which are summarised
3 sensors MW continuous
3 sensors which are summarised
1 sensor running
Ongoing measurement without mean value calculator with 1 sensor
Issue of manual value
No measurement, simulation of measured value only
Batch cross-sections
Allows weighted mean value calculation, as well as a curve switching with fine batching.
Coarse flow = fine flow
No curve switching
Fine flow = 0
Discontinuation of the measurement with fine signal, only
the coarse flow is measured
Coarse flow > fine flow
Curve switching with fine batching, the fine flow delivers a
different measuring signal
Examples:
One sensor, no coarse-fine switching:
One sensor, coarse-fine switching via material flow reduc-
tion (1/2-open position):
Sensor1 only measures coarse flow,
both sensors no curve switching.
Sensor1 measures coarse flow only, Sensor2 features
curve switching with fine batching as the fine flow is re-
duced by the 1/2-open position.
A pulsating fine batching can not be measured.
Temperature
Activate this channel?
If no check mark is ticked, no temperature is measured.
Measuring cycle
Standard value 1.