Take sample
To obtain a material-specific balance, it is necessary to take samples from the flowing material as the meas-
ured parts are being recorded. The weight moistures of the samples are determined in the laboratory by
drying or via „Karl Fischer Titration“. When creating the calibration curves, the measured parts are allocated
to the laboratory samples.
WARNING
Drives start up automatically.
Body parts and clothing are drawn into machinery.
The samples, in most cases, must be taken in immediate proximity of the running machine parts.
Use suitable aids to pull the samples. Keep sufficient safety distance.
Recording with Start
The next batching procedure is recorded in the „..MW batch“ measuring
mode.
Continuous recording
The recording is stopped or started immediately.
Joining the points
The measuring points in the graph are connected with lines.
Deleting
The recording is deleted via an additional confirmation.
Selecting signals
Using the switches for parts, moisture, temperature and output, the repre-
sentation of the signals in the graph can be switched on and off.
When creating the calibration curves, only the measured parts (parts 1.. 3)
need to be switched on.
Evaluation
The quality of the recorded sample can be read off at the curve gradient.
If this can be guaranteed, the range of the sample can be limited using
both red dashed indicators.
The mean value of all fraction values between the indicators is displayed
and yields the fraction value of a sample.
This value is to be noted (copy into the clipboard) and allocated to the
laboratory value of the sample in the "curves" register.
The sampling rate can be determined under „configuration / take cycle
sample“.