31
Single event sound exposure level
(
L
AE
)
measurement
<
Parameter setting
>
1
)
The key operation is similar to the measurement of A-weighted sound pressure level
(L
A
) except that it needs [Start/Stop] key input for starting the measurement
(automatic calculation).
2
)
To display the value L
E
, keep the "LAE” key ON in advance in the <View Mode> 3/3
①
Frequency weighting key
:
A,C or Z
②
Display mode key
:
L
E
③
Time weighting key
:
Any of F, S or Imp (doesn't influence the measurement)
④
[Range] key
:
Select a range where the bar graph indicates
approximately 2/3 of the full scale.
【
Method of selecting [Range] key
】
Press [Range] key, and choose by cursor keys
▲▼
, and press [Range] key
again to register.
⑤
Measuring time key
:
1s, 3s, 5s, 10s, 1m, 5m, 10m, 15m, 30m, 1h, 8h, 24h
and
***
(to the [Start/Stop] key)
3) The measurement starts with [Start/Stop] key.
<
Display
>
・
The measurement is similar to the equivalent continuous A-weighted sound pressure level.
1s 000h00m00s
63.5 dB
40
130
Stp
A Fast
L
E
Time weighting
:
Any of F, S or Imp (doesn't
influence the measurement.)
Frequency weighting
:
A,C or Z
Display mode
L
E
Measuring
time
Rec:Blinks during
recording
Stp: Holding state
<View Mode> 3/3
Lp :INST
(A)view LA05:OFF
LAeq :OFF LA10:OFF
LAE :ON LA50:OFF
LAmin
:OFF LA90:OFF
LAmax :OFF LA95:OFF
<
Menu
>
②
Display
mode key
④
[Range] key
③
Time weighting
key
(
F:Fast, S:Slow)
⑤
Measuring
time key
2)[Menu] key
①
Frequency
weighting key
(A
・
C, Z)
Summary of Contents for 6236
Page 1: ...Sound Level Meter TYPE 6236 Instruction Manual ACO Co Ltd...
Page 53: ...52 Appearance diagram of Sound Level Meter TYPE 6236...
Page 72: ...Sound Level Meter TYPE 6236 Instruction guide ACO Co Ltd...