Event Message for PEF Action (Available if the item-PEF Support is enabled)
This enables of disables Event Messages for PEF action. Refer to Table 24.6 of the IPMI 1.5 Specification for more information
at www.intel.com. The options are Disabled and Enabled.
Allows the BMC to reset or power down the system if the operating system hangs or crashes. The options are Disabled, Reset
System, Power Down, Power Cycle.
BMC Watch Dog TimeOut [Min:Sec]
This option appears if BMC Watch Dog Timer Action (above) is enabled. This is a timed delay in minutes or seconds, before a
system power down or reset after an operating system failure is detected. The options are [5 Min], [1 Min], [30 Sec], and [10
Sec].
XEvent Log Configuration
View Event Log
Use this option to view the System Event Log.
Mark all events as read
This option marks all events as read. The options are OK and Cancel.
Clear event log
This option clears the Event Log memory of all messages. The options are OK and Cancel.
PCI Error Log
Use this option to enable PCI error (PERR) logging. The options are Yes and No.
7-4
Security Settings
The AMI BIOS provides a Supervisor and a User password. If you use both pass- words, the Supervisor password must be set
first.