![Acer X1130P Series Service Manual Download Page 72](http://html.mh-extra.com/html/acer/x1130p-series/x1130p-series_service-manual_2839288072.webp)
72
Optical Problems Checking Items
No. Item
Trouble Shooting Guide
1
Brightness
1. Change lamp
2
Uniformity
1. Change lamp
3
FOFO Contrast
1. Check ADC calibration
2. Check user’s menu brightness & contrast are default
3. Clean DMD
4. Clean PL
5. Check ILL stop assy
4
ANSI Contrast
1. Clean PL
2. Clean DMD
3. Change PL
5
Color
1. Check color wheel delay
2. Check CW 50% point. Replace CW if necessary
6
Color Uniformity
1. Change lamp
7
Blue Edge
1. Refer to next page
2. Change CM
3. Change SUB HSG
8
Blue/Purple Border
1. Refer to next page
2. Change CM
3. Change SUB HSG
9
Focus
1. Change Projection Lens
2. Check PL datum and DMD parallel
10
Dust
Clean DMD
11
Horizontal/Vertical
Strips
1. Check connector between chip BD and Main BD
2. Re-install DMD with chip BD
3. Check if any pin of C-Spring is missing, damaged or dirty
4. Change new Chip BD/C-Spring
5. Change new DMD
12
Pixel Fail
Change new DMD
Summary of Contents for X1130P Series
Page 16: ...16 System Block Diagram ...
Page 17: ...17 Product Overview ...
Page 18: ...18 ...
Page 19: ...19 ...
Page 20: ...20 ...
Page 45: ...45 Fig 3 3 Fig 3 4 Fig 3 5 Fig 3 6 Datum1 Datum2 Datum3 Clip UP CM Sponge ...
Page 58: ...58 ...
Page 61: ...61 Confirm the position of EMI cord right Screw Screw ...
Page 64: ...64 12 Front IR wire to MB alignment Front IR wire should align in to these grooves ...
Page 74: ...74 Power Supply Problems Checking Flow ...
Page 84: ...84 Chapter 5 FRU List Exploded Diagram Module 1 Total Exploded View ...
Page 85: ...85 ...
Page 86: ...86 Module 2 ASSY UPPER CASE ...
Page 87: ...87 Module 3 ASSY LOWER CASE ...
Page 88: ...88 Module 4 ASSY FRONT CASE ...
Page 95: ...95 X1130PA X1230PK X1230P X1230PA X1237 Customer code 0813 ...