5
1.0 Optical Performance
Tested under 60” (diagonal) image size with Wide
projection lens position unless other specified.
1.1 ANSI Brightness
X1130P/X1130PA/
X1230P
: Minimum 2000 Lumens
X1230PK/
X1230PA
: Minimum 1840 Lumens
X1237 Minimum 2400 Lumens
1.2 Brightness Uniformity
1.2.1 ANSI Uniformity Minimum 55%
1.2.2 JBMA Uniformity
Minimum 75%
1.2.3 Upper-Down
unbalance
0.5~2
1.2.4 Left-Right
unbalance
0.6~1.67
1.3 Contrast Ratio
1.3.1 ANSI Contrast
Minimum 150:1
1.3.2 FOFO Contrast
without APM
X1130P/X1130PA/
X1230P/ X1237
: Minimum 1600:1
X1230PK/
X1230PA
: Minimum 1100:1
1.3.3 FOFO Contrast with
APM
X1130P/X1130PA/
X1230P/ X1237
: Minimum 2100:1
X1230PK/
X1230PA
: Minimum 1200:1
1.4 Light Leakage
1.4.1 Light Leakage in
Active Area
<0.5 lux compared to center point within 60” (Diagonal at
2.3m, Wide) image size. Note: This light leakage in Active
area is only described as the spot light with obvious shape.
It is not included the uniformity difference of the projector for
black pattern.
1.4.2 Light Leakage out of
Active Area
(Except DMD Defect)
<0.5 lux with 60”~80“(Diagonal at 2.3m, Wide) image size
1.5 Color
X
Y
1.5.1 White
0.314±0.04
0.377±0.04
1.5.2 Red
0.647±0.04
0.341±0.04
1.5.3 Green
0.344±0.04
0.587±0.04
1.5.4 Blue
0.139±0.03
0.090±0.03
1.6 Color Uniformity
X
Y
1.6.1 White
0.040
0.040
1.6.2 Red
0.040
0.040
1.6.3 Green
0.040
0.040
1.6.4 Blue
0.040
0.040
1.7 Color Gamut
Typ 60% compare NTSC
2.0 Image Quality
2.1 Throw Ratio
52.5”±3% Diagonal at 2m, Wide
2.2 Zoom Ratio (tolerance
applied)
1.1±2%
2.3 Distortion
2.3.1 Keystone Distortion
<1.0%
2.3.2 Vertical TV
Distortion
<1.0%
2.4 Projection Offset
120% ±5%
2.5 Focus Range
2.5.1 Visible Range
1~8 m
Summary of Contents for X1130P Series
Page 16: ...16 System Block Diagram ...
Page 17: ...17 Product Overview ...
Page 18: ...18 ...
Page 19: ...19 ...
Page 20: ...20 ...
Page 45: ...45 Fig 3 3 Fig 3 4 Fig 3 5 Fig 3 6 Datum1 Datum2 Datum3 Clip UP CM Sponge ...
Page 58: ...58 ...
Page 61: ...61 Confirm the position of EMI cord right Screw Screw ...
Page 64: ...64 12 Front IR wire to MB alignment Front IR wire should align in to these grooves ...
Page 74: ...74 Power Supply Problems Checking Flow ...
Page 84: ...84 Chapter 5 FRU List Exploded Diagram Module 1 Total Exploded View ...
Page 85: ...85 ...
Page 86: ...86 Module 2 ASSY UPPER CASE ...
Page 87: ...87 Module 3 ASSY LOWER CASE ...
Page 88: ...88 Module 4 ASSY FRONT CASE ...
Page 95: ...95 X1130PA X1230PK X1230P X1230PA X1237 Customer code 0813 ...