33
Serial Number Upgrade SOP
Hardware required
1. Standard RS232 Download cable
2. Personal computer or laptop computer
Software required
1. Acer_Service_Tool(Data)_3.1.exe
When need to use this Serial Number Upgrade program:
When it’s time to replace Main board for repair, it’s necessary to rewrite original S/N and
some adjustment values into new Main board by the following process.
Upgrade procedure
1. Prepare the download equipment: RS232 cable connect to PC and projector
2. Plug power cord into projector, and the projector will be in stand by mode.
3. Execute “Acer_Service_Tool(Data)_3.1.exe”, and it will appear as below picture.
4. Change to connected COM port and Click “Port Open” icon.
5.
Read data from original Main board:
Click “Read system Data”, and it will read the Adjustment data (except Auto keystone
data) & Serial Number from projector and show the “Read complete” message in
information block.
4-1. Change to
connected COM Port
number
4-2. Click “Port
Open”
5-1. Click this icon to
read all data
5-2. Show “Read
Complete!”
Summary of Contents for X1130P Series
Page 16: ...16 System Block Diagram ...
Page 17: ...17 Product Overview ...
Page 18: ...18 ...
Page 19: ...19 ...
Page 20: ...20 ...
Page 45: ...45 Fig 3 3 Fig 3 4 Fig 3 5 Fig 3 6 Datum1 Datum2 Datum3 Clip UP CM Sponge ...
Page 58: ...58 ...
Page 61: ...61 Confirm the position of EMI cord right Screw Screw ...
Page 64: ...64 12 Front IR wire to MB alignment Front IR wire should align in to these grooves ...
Page 74: ...74 Power Supply Problems Checking Flow ...
Page 84: ...84 Chapter 5 FRU List Exploded Diagram Module 1 Total Exploded View ...
Page 85: ...85 ...
Page 86: ...86 Module 2 ASSY UPPER CASE ...
Page 87: ...87 Module 3 ASSY LOWER CASE ...
Page 88: ...88 Module 4 ASSY FRONT CASE ...
Page 95: ...95 X1130PA X1230PK X1230P X1230PA X1237 Customer code 0813 ...