87
Chapter 4
System Check Procedures
Power System Check
If the system will power on, skip this section. Refer to System External Inspection.
If the system will not power on, do the following:
•
Check if the power cable is properly connected to the system and AC source.
•
Check if the voltage selector switchis set to the correct voltage setting.
System External Inspection
1.
Inspect the LED indicators on the front panel, which can indicate the malfunction.
2.
Make sure that air flow is not blocked.
3.
Make sure nothing in the system is making contact that could short out power.
4.
If the problem is not evident, continue with System Internal Inspection.
System Internal Inspection
1.
Turn off the system and all the peripherals connected to it.
2.
Unplug the power cord from the power outlets.
3.
Unplug the power cord from the system.
4.
Unplug all peripheral cables from the system.
5.
Place the system unit on a flat, stable surface.
6.
Remove the system covers.For instructions on removing system covers, refer to “System Disassembly”
on page 23.
7.
Verify that components are properly seated.
8.
Verify that all cable connectors inside the system are firmly and correctly attached to their appropriate
connectors.
9.
Verify that all components are Acer-qualified and supported.
10.
Replace the system covers.
11.
Power on the system.
12.
If the problem with the system is not evident, you can try viewing the POST messages and BIOS event
logs during the system startup.
Summary of Contents for Aspire G3610
Page 1: ...Acer Predator G3610 Service Guide PRINTED IN TAIWAN ...
Page 12: ...4 Chapter 1 Block Diagram ...
Page 48: ...40 Chapter 3 d Remove the three screws e Pull the bracket of removable HDD from the chassis ...
Page 74: ...66 Chapter 3 Install the I O Shielding 1 Install I O shielding into chassis ...
Page 76: ...68 Chapter 3 5 Connect the ATX 24Pin Power cable and ATX 4Pin Power cable to main board ...
Page 91: ...Chapter 3 83 3 Close the PCI Latch then fix the four screws ...
Page 101: ...93 Chapter 4 b Select Proceed with flash update and Press Enter ...
Page 103: ...Chapter 5 95 M B Placement Jumper and Connector Information Chapter 5 ...