Carefully read and follow all safety instructions in this manual 

or on pump.

This is the safety alert symbol.

 When you see this symbol 

on your pump or in this manual, look for one of the following 

signal words and be alert to the potential for personal injury!

warns about hazards that 

will

 cause serious per-

sonal injury, death or major property damage if ignored.

warns about hazards that 

can

 cause serious per-

sonal injury, death or major property damage if ignored.

warns about hazards that 

will

 or 

can

 cause minor 

personal injury or property damage if ignored.

The word 

NOTICE  

indicates special instructions which are import-

ant but not related to hazards.

To avoid serious or fatal personal injury and possible property 

damage, carefully read and follow the safety instructions.

1.

 

Under certain conditions, submersible pumps 

can develop extremely high pressure. Install a 

pressure relief valve capable of passing 

entire pump flow at 75 PSI (517kPa) when 

using an air over water pressure tank. Install 

a pressure relief valve capable of passing entire pump flow 

at 100 PSI (690 kPa) when using a pre-charged pressure 

tank.

Do not allow pump, pressure tank, piping, or any other 

system component containing water to freeze. Freezing 

may damage system, leading to injury or flooding. Allowing 

pump or system components to freeze will void warranty.

2.

 

Hazardous

voltage

Can shock, burn or cause death. To avoid 

dangerous or fatal electric shock hazard, use 

pump only in a water well.

Risk of dangerous or fatal electrical shock.

 Do 

not install this pump in any pond, river, or other open body of water 

that could be used for swimming or recreation. Do not swim, wade 

or play in a body of water in which a submersible pump has been 

installed.

Install, ground and wire pump according to local and Cana-

dian Electrical Code or National Electrical Code requirements 

that apply.
Disconnect electrical power supply before installing or servic-

ing pump.
Make sure line voltage and frequency of power supply match 

motor nameplate voltage and frequency.

3.  Install pump according to all plumbing, pump and well code 

requirements.

4.  Test well water for purity before using well. Call your local health 

department for testing procedure.

5.  During installation, keep well covered to prevent leaves and for-

eign matter from falling into well. Foreign objects in well can con-

taminate water and cause serious mechanical damage to pump.

6.  Pipe joint compound can cause cracking in plastics. Use only 

teflon tape when sealing joints in plastic pipe or connecting pipe 

to thermoplastic pumps.

California Proposition 65 Warning

This product and related accessories contain chem-

icals known to the State of California to cause cancer, birth defects 

or other reproductive harm.

PRE-INSTALLATION

Inspect pump and motor for delivery damage. Report any damage 

immediately to shipping carrier or to your dealer.
Well driller should thoroughly develop well (pump out all fine sand 

and foreign matter) before pump is installed. (See Initial Startup).
Pump performance is based on pumping clear, cold water with no 

entrained air.

Warranty is void in the following conditions:
 •  Pump has pumped excessive sand which can cause premature 

wear to pump. (See Initial Startup)

 •  Water is corrosive.
 •  If entrained gas or air present in water being pumped, reduce 

flow and cause cavitation which can damage pump.

 •  Pump has been operated with discharge valve closed – severe 

internal damage will result.

Install pump at least 15 to 20’ (4.6 - 6.1M) below the lowest water 

level reached with pump running (lowest draw-down water level), 

and at least 5’ (1.5M) above bottom of well.

ELECTRICAL

WIRING/GROUNDING

 

Can shock, burn, or cause death.  

 

Permanently ground pump, motor  

 

and control   box before connecting  

 

power supply to motor.

Ground pump and motor in accordance with all codes and ordinanc-

es that apply. Use copper ground wire at least as large as wires 

carrying current to motor.
Motor is supplied with copper ground wire. Splice to copper con-

ductor that matches motor wire size specified in Table 3. See “cable 

splicing” under Installation.
Permanently ground pump, motor and control box before connecting 

power cable to power supply. Connect ground wire to approved 

ground first, then connect to equipment being installed.

Do not ground to gas supply line.

Fire and electrical shock hazard.

 If using a power 

supply wire larger than No. 10 (5mm

2

) (for example, No. 8 (7mm

2

wire) between pump and control box, run wire to separate junction 

box. Connect junction box to control box with a No. 10 (5mm

2

) wire.

For more information, contact your local code officials.

WIRING CONNECTIONS

All wiring must meet Canadian Electrical Code or National Electrical 

Code and local code requirements.
Use only copper wire for connections to pump and control box.
To avoid over-heating wire and excessive voltage drop at motor, be 

sure wire size is at least as large as size listed in Table 3 for your 

horsepower pump and length of wire run.

NOTICE: 

See Installation Wiring Diagrams for typical wiring hook-

ups and control box identification.

Table 1: Recommended Fusing Data - 60 Hz, Single  

 

Phase, 3 Wire Submersible Pump Motors

Table 2:  Recommended Fusing Data - 60 Hz, Single 

Phase, 2 Wire Submersible Pump Motors

2

 

 

 

Fuse Size

    

 

Service  Locked                             

  

 

Factor  Rotor

  HP 

Volts  Amps 

Amps  Standard  Dual Elem  C.B.

 

1/2 230 6.3  20.5  15 

10 

15

 3/4 

230 

8.2 

28.3 

25 

15 

20

 1 

230  10.8 

41.0 

30 

15 

25

  1-1/2  230 

13.7 

46.5 

40 

20  

30

Hazardous

voltage

 

 

 

Fuse Size

    

 

Service  Locked                             

  

 

Factor  Rotor

  HP 

Volts  Amps  Amps  Standard  Dual Elem  C.B.

 1/2 

230 

5.0 

19.6 

15 

10 

10

 3/4 

230 

6.0 

24.0 

15 

10 

15

 1 

230 

7.6 

36.9 

20 

15 

20

Summary of Contents for ACE 1/2 2W

Page 1: ...4 2W ACE 1 2W Three Wire Submersibles with Ground Models ACE 1 2 3W ACE 3 4 3W ACE 1 3W ACE 1 1 2 3W ACE 1 3W 18 WARRANTY Product defects covered for 36 months from date of purchase Receipt is require...

Page 2: ...a to cause cancer birth defects or other reproductive harm PRE INSTALLATION Inspect pump and motor for delivery damage Report any damage immediately to shipping carrier or to your dealer Well driller...

Page 3: ...above use magnetic starter to avoid damage to pressure switch Consult factory for wiring information Fig 1A 3 wire 1 2 thru 1 HP quick disconnect box Follow color coding when connecting control box Y...

Page 4: ...ck connections E Center tubing over butt connector and apply heat evenly with torch match or lighter will not supply enough heat NOTICE Keep torch moving Too much concentrated heat may damage tubing s...

Page 5: ...eal or pitless adapter unit well unit electri cal conduit and surface piping Installation must meet all code requirements that apply CONNECTING TO TANK WATER SYSTEM Hazardous pressure Submersible pump...

Page 6: ...e Union Submersible motor control 3 wire models Electrical disconnect Pressure gauge Air volume control Pressure switch To house service Gate valve Relief valve 2 ft 6m See table Figure 11 Typical Pre...

Page 7: ...nameplate or on circuit Use only control box designed for use with pump rating diagram inside control box cover Wire size too small Check wire size against chart Page 3 Install correct wire size Pump...

Page 8: ...ble and does not apply to products used in commercial rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact ACE Customer Service Sewage pump...

Page 9: ...dangers relatifs la reproduction PR PARATION L INSTALLATION S assurer que la pompe et le moteur n ont subi aucun dommage pendant la livraison Signaler imm diatement tout dommage au transporteur ou au...

Page 10: ...chement rapide monophas 3 fils de 1 2 1 CV Respecter le codage par couleur pour le branchement de la bo te de commande Le jaune avec Y le rouge avec R le noir avec B Ensemble monophas 2 fils Les pompe...

Page 11: ...la gaine sur le connecteur bout bout et r partir la chaleur uni form ment au moyen d un chalumeau des allumettes ou un briquet ne fournissent pas assez de chaleur REMARQUE D placer constamment la fla...

Page 12: ...au soit bien claire 9 D poser le robinet vanne en vue de son installation d finitive pr s du r s ervoir voir Fig 11 et 12 10 Monter le plombage sanitaire du puits ou l ensemble adaptateur sans cavit l...

Page 13: ...124 2 18 206 8 30 344 7 50 193 1 28 275 8 40 413 7 60 262 38 Couvercle de puits ventil Bo te de com mande 3 types de c blage Sectionneur de courant R servoir pression pr char g e Manocontact Jauge de...

Page 14: ...le sch ma du circuit couvercle de la bo te commande con ue sp cialement pour cette pompe de commande Calibre de fil trop mince Comparer le calibre du fil avec le tableau de la page 10 Installer le fil...

Page 15: ...es fins commerciales ou de location Pompes d eaux d gout NE PAS RETOURNER une pompe d eaux d gout qui a t install e au d taillant Communiquer avec le service la client le de ACE Les pompes d eaux d go...

Page 16: ...presencia de da os Informe de inmediato al transportista o al concesionario de la bomba sobre todo da o ocurrido El perforador del pozo debe limpiar perfectamente el pozo bombearlo hasta extraer toda...

Page 17: ...ica Figura 1A Motor monof sico 3 alambres caja de desconex i n r pida para motores de 1 2 a 1 hp Cuando conecte la caja de control siga las si as de color Amarillo para Y Rojo para R Negro para B Mono...

Page 18: ...on exiones E Centre el tubo de pl stico sobre el conector de tope conector de cubre junta y aplique calor en forma pareja con un soplete un f sforo o un encendedor no dan suficiente calor AVISO Manten...

Page 19: ...tire la v lvula de cortina para su instalaci n permanente cerca del tan que v anse las figs 11 y 12 10 Instale un sello sanitario para pozo o una unidad adaptadora la unidad del pozo los conductos par...

Page 20: ...50 344 7 28 193 1 40 275 8 60 413 7 38 262 DISTANCIA DE LA V LVULA DE RETENCI N AL ORIFICIO DE PURGA SUPERIOR CAPACIDAD DEL DISTANCIA en PIES m TANQUE en GALONES l 42 159 2 0 6 82 310 4 3 0 9 120 454...

Page 21: ...la bomba en el interior sobre la tapa de la caja de control El di metro de los conductores es Verifique el di metro de los conductores en el cuadro de la p gina 17 Instale alambrado de di metro corre...

Page 22: ...re productos utilizados en aplicaciones comerciales o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n...

Page 23: ...23 This page intentionally left blank...

Page 24: ......

Reviews: