Page 1: ...4 2W ACE 1 2W Three Wire Submersibles with Ground Models ACE 1 2 3W ACE 3 4 3W ACE 1 3W ACE 1 1 2 3W ACE 1 3W 18 WARRANTY Product defects covered for 36 months from date of purchase Receipt is require...
Page 2: ...a to cause cancer birth defects or other reproductive harm PRE INSTALLATION Inspect pump and motor for delivery damage Report any damage immediately to shipping carrier or to your dealer Well driller...
Page 3: ...above use magnetic starter to avoid damage to pressure switch Consult factory for wiring information Fig 1A 3 wire 1 2 thru 1 HP quick disconnect box Follow color coding when connecting control box Y...
Page 4: ...ck connections E Center tubing over butt connector and apply heat evenly with torch match or lighter will not supply enough heat NOTICE Keep torch moving Too much concentrated heat may damage tubing s...
Page 5: ...eal or pitless adapter unit well unit electri cal conduit and surface piping Installation must meet all code requirements that apply CONNECTING TO TANK WATER SYSTEM Hazardous pressure Submersible pump...
Page 6: ...e Union Submersible motor control 3 wire models Electrical disconnect Pressure gauge Air volume control Pressure switch To house service Gate valve Relief valve 2 ft 6m See table Figure 11 Typical Pre...
Page 7: ...nameplate or on circuit Use only control box designed for use with pump rating diagram inside control box cover Wire size too small Check wire size against chart Page 3 Install correct wire size Pump...
Page 8: ...ble and does not apply to products used in commercial rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact ACE Customer Service Sewage pump...
Page 9: ...dangers relatifs la reproduction PR PARATION L INSTALLATION S assurer que la pompe et le moteur n ont subi aucun dommage pendant la livraison Signaler imm diatement tout dommage au transporteur ou au...
Page 10: ...chement rapide monophas 3 fils de 1 2 1 CV Respecter le codage par couleur pour le branchement de la bo te de commande Le jaune avec Y le rouge avec R le noir avec B Ensemble monophas 2 fils Les pompe...
Page 11: ...la gaine sur le connecteur bout bout et r partir la chaleur uni form ment au moyen d un chalumeau des allumettes ou un briquet ne fournissent pas assez de chaleur REMARQUE D placer constamment la fla...
Page 12: ...au soit bien claire 9 D poser le robinet vanne en vue de son installation d finitive pr s du r s ervoir voir Fig 11 et 12 10 Monter le plombage sanitaire du puits ou l ensemble adaptateur sans cavit l...
Page 13: ...124 2 18 206 8 30 344 7 50 193 1 28 275 8 40 413 7 60 262 38 Couvercle de puits ventil Bo te de com mande 3 types de c blage Sectionneur de courant R servoir pression pr char g e Manocontact Jauge de...
Page 14: ...le sch ma du circuit couvercle de la bo te commande con ue sp cialement pour cette pompe de commande Calibre de fil trop mince Comparer le calibre du fil avec le tableau de la page 10 Installer le fil...
Page 15: ...es fins commerciales ou de location Pompes d eaux d gout NE PAS RETOURNER une pompe d eaux d gout qui a t install e au d taillant Communiquer avec le service la client le de ACE Les pompes d eaux d go...
Page 16: ...presencia de da os Informe de inmediato al transportista o al concesionario de la bomba sobre todo da o ocurrido El perforador del pozo debe limpiar perfectamente el pozo bombearlo hasta extraer toda...
Page 17: ...ica Figura 1A Motor monof sico 3 alambres caja de desconex i n r pida para motores de 1 2 a 1 hp Cuando conecte la caja de control siga las si as de color Amarillo para Y Rojo para R Negro para B Mono...
Page 18: ...on exiones E Centre el tubo de pl stico sobre el conector de tope conector de cubre junta y aplique calor en forma pareja con un soplete un f sforo o un encendedor no dan suficiente calor AVISO Manten...
Page 19: ...tire la v lvula de cortina para su instalaci n permanente cerca del tan que v anse las figs 11 y 12 10 Instale un sello sanitario para pozo o una unidad adaptadora la unidad del pozo los conductos par...
Page 20: ...50 344 7 28 193 1 40 275 8 60 413 7 38 262 DISTANCIA DE LA V LVULA DE RETENCI N AL ORIFICIO DE PURGA SUPERIOR CAPACIDAD DEL DISTANCIA en PIES m TANQUE en GALONES l 42 159 2 0 6 82 310 4 3 0 9 120 454...
Page 21: ...la bomba en el interior sobre la tapa de la caja de control El di metro de los conductores es Verifique el di metro de los conductores en el cuadro de la p gina 17 Instale alambrado de di metro corre...
Page 22: ...re productos utilizados en aplicaciones comerciales o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n...
Page 23: ...23 This page intentionally left blank...
Page 24: ......