4
STEP 4 Protective Relay Module (PRM) Connections
The Protective Relay Module is the output controller for heat alarm options and accessories.
Locate the Protective relay module near the Intelabox.
Connect the IntelaBox Heat Alarm Option Cable
(Gray Cable with black connector)
to Protective Relay Module (PRM).
Connect the IntelaBox 18 Gauge Red Male Wire W/3A fuse to the Red Female wire off the
PRM.
Attach the
PRM Black Ground
(PIN 12) wire to a chassis ground.
Attach PRM's
Red Battery wire
to
uninterrupted Battery Power.
This connection point
must be rated to supplying 40A of power. Attach 40A
Fuse at connection point.
Battery connection must be direct. Do not use a device that automatically
removes power to vehicle and connected system that notify the K9 handler when
the system activates
.
This system has features designed to operate with the IGNITION OFF
.
When power is connected, the head will power up briefly and turn itself off. Continue with
install.
Installing K9 Heat Alarm
®
Pro alert features