background image

Installation Manual  I  Installation

8

MP4010-1903

3.5.2 Double Stand Installation Instructions

The AccuTemp double stand can be equipped with adjustable 
height feet or can be equipped with non-adjustable casters and 
accommodates (2) E6 model Evolutions (FIGURE 4). 
1.  Before mounting a steamer on a stand with casters engage 

the brakes on the two front locking casters, pressing on the 
“ON” handle of the brake mechanism. 

2.  Always mount the first EVOLUTION on the bottom of the 

stand. To mount the bottom steamer, carefully lift and place 
it on the horizontal mounting brackets, ensuring that the (4) 
mounting holes on the underside of the Evolution are lined 
up with the mounting holes on the brackets. 

3.  Then, using a 7/16” wrench, fasten one pair of the 1/4”-20 

hex bolts and 1/4” split lock washers through the underside 
of each stand bracket mounting hole into the Evolution and 
tighten securely.

4.  Once the bottom steamer has been installed, carefully 

lift and place the top Evolution steamer on the horizontal 
mounting brackets, ensuring that the (4) mounting holes 
on the underside of the Evolution are lined up with the 
mounting holes on the brackets. 

5.  Then, using a 7/16” wrench, fasten one pair of the 1/4”-20 

hex bolts and 1/4” split lock washers through the underside 
of each stand bracket mounting hole and tighten securely. 

6.  With the SNH-20 stand, level the appliances by adjusting the 

feet found at the ends of each stand leg, either up or down 
as needed.

3.5.3 Flush Mount Installation

To Flush mount the appliance to a counter, follow these steps:
1.  Drill 4 holes as seen in FIGURE 2.
2.  Attach the appliance to counter top with (4) 1/4-20 x 3/4” 

hex head bolts and 1/4-20 split lock washers.

3.  Apply a bead of high temp food grade silicone caulking 

around the perimeter and smooth out.

FIGURE 2

FIGURE 4: MANUAL UNITS ON A DOUBLE STAND

FIGURE 3: MANUAL FILL UNIT ON SINGLE STAND

Summary of Contents for EVOLUTION Series

Page 1: ...installation initial field start up and complete the equipment adjustments described in this manual IMPORTANT WARRANTY INFORMATION WARRANTY REGISTRATION STARTUP FORM INSIDE THIS MANUAL MUST BE REMOVED...

Page 2: ...GENERAL INFORMATION PAGE 5 INSTALLATION PAGE 7 OPERATION USE PAGE 14 OPERATION CLEANING PAGE 18 TROUBLESHOOTING PAGE 21 SERVICE PAGE 22 PREVENTATIVE MAINTENANCE CHECKLIST PAGE 23 WARRANTY PAGE 24 DOC...

Page 3: ...e do not attempt to operate this appliance Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance...

Page 4: ...ns Name Technicians Email Additional Info 1 Is the steamer being installed at an altitude greater than 2 000 feet Tick Box 2 Is the steamer level Tick Box 3 Is the wall receptacle positioned in a low...

Page 5: ...n less YES NO Type of NEMA Plug Tick One Tick One L6 30P 208 240V 6kW L16 20P 480V 14kW L15 30P 208 240V 10kW IEC 60309 2 230 415V 15 50P 208 240V 15kW 15 Does the Low Water Light and Alarm turn OFF o...

Page 6: ...used here draw attention to activities that may influence safety health protection and the necessity for servicing They help you to prevent problems and the advice will make your work easier WARNING I...

Page 7: ...the base model E Electric B is the size of the unit 6 pan CCC is the supply Voltage D is the number of phases 1 or 3 E is the control series D Manual Fill E Autofill F is the energy input G is the ti...

Page 8: ...ult in performance faults Only professional installation of the device guarantees it high quality operation Check proper setting of the equipment by placing a hotel pan filled with water inside the st...

Page 9: ...ounting hole into the Evolution and tighten securely 4 Once the bottom steamer has been installed carefully lift and place the top Evolution steamer on the horizontal mounting brackets ensuring that t...

Page 10: ...d must be filled throughout the cooking process to assure consistent cook times Do not use the Low Water Indicator as your indication that this steamer requires water as this actually turns off the he...

Page 11: ...pplied with single or 3 phase 3 For use on individual branch circuit only 4 Do not connect to a circuit operating at more than 150V to ground 5 Dimensions outside brackets are inches in brackets are m...

Page 12: ...e steamer If hot is used temperature must be less than 180 F The hose must not be sharply bent kinked or twisted If the steamer is close to a wall use a right angle fitting to prevent kinking the hose...

Page 13: ...ng should have no restrictions and no low spots where water can accumulate Ventilation piping can be directed upwards toward hoods or downward towards floor drains Slightly different approaches are re...

Page 14: ...e steamer vent to a floor drain to allow water condensing in it to run unimpeded into the floor drain 3 For downward sloping extension to a floor drain ONLY ID or larger reinforced silicone hose auto...

Page 15: ...brushes metal scouring pads to clean the cooking chamber bottom 4 1 Operation Introduction The AccuTemp Evolution steamer uses the time proven method of cooking with steam Once the cooking time expire...

Page 16: ...lation Manual I Operation 15 MP4010 1903 OPERATOR DISPLAY COOK or HOLD DISPLAY TEMPERATURE OVER TEMPERATURE LAMP HIGH WATER LAMP LOW WATER LAMP SET TIMER INCREASE VARIABLE DECREASE VARIABLE ON OFF FIG...

Page 17: ...the steamer The display will indicate PrE while in Cook Mode and the temperature while in the Hold Mode 2 Once the steamer is preheated and ready to cook the display will indicate the COO Cook Mode or...

Page 18: ...food into the cooking chamber Shut the door 3 Food will be held at the preset holding temperature The factory default setting is set at 180 F 4 Depress the DISP TEMP button to display the current cook...

Page 19: ...condensate tray with a clean cloth FIGURE 19 Clean the door gasket inside of door and front face of the cooking chamber Clean water sensors with a non metallic cleaning pad Wipe down corners of cooki...

Page 20: ...of the steam collector align the 4 retaining fasteners and hand tighten then install the pan rails and the condensate tray Leave the door open overnight NOTE The steamer will not operate without the...

Page 21: ...activate the chromium oxide passive layer 8 Always rinse the unit with clean water and dry with the steamer door and drain valve open 4 7 5 How to to Protect Stainless Steel All materials used in manu...

Page 22: ...cooking cabinet 5 4 Steamer Does Not Heat If the operators display doesn t light up see Section 5 1 Verify the steamer door is closed as the unit will not heat when the door is open 5 5 Steam Comes Ou...

Page 23: ...ducts Inc Technical Service Department or the service call may not be covered by the limited warranty WARNING Only an AccuTemp Products Inc Authorized Service Personnel or Representative must perform...

Page 24: ...stand casters Monthly Inspect AC power cord for degradation or bare wires Replace if defective or suspect X Inspect door gasket for cuts and degradation Replace if damaged We suggest replacing once a...

Page 25: ...s or workmanship provided the service agency has received advance approval from AccuTemp factory service to perform the repair or replacement This warranty includes travel time not to exceed two hours...

Page 26: ......

Page 27: ...AccuTemp Product Inc Technical Customer Support Technician is available Monday thru Sunday 7 00am to 7 00pm EST 800 480 0415 or 260 469 3040 Phone 800 480 0415 or 260 469 3040 Email service accutemp...