background image

Ethernet Modual

Fun

Byte count

Data

01H

01H

02H

The content of the data is,

7

6

5  

4

3

2

1

0

0

0

0

0

0

1

0

      MSB                                               LSB

Relay 1 = OFF , Relay 2=ON

Table 3-6 Read 2 Relays Status Response Message

2) Read Status of DI (Function Code 02)

Function Code 02

1=On 

 

 

0=Off

There are 38 DIs in Acuvim II, and the start address is 0000H.

The following query is to read the 4 DIs Status of address 1 of Acuvim II.

Query

Transaction 

identifier hi

Transaction 

identifier lo

Protocol 

identifier hi

Protocol 

identifier lo

Length hi Length lo

Unit 

identifier

00H

00H

00H

00H

00H

06H

01H

Fun

Data start reg hi Data start reg lo

Data #of regs hi

Data #of regs lo

02H

00H

00H

00H

04H

Table 3-7 Read 4 DIs Query Message 

Response

The  response  includes  MBAP  Header,  function  code,  quantity  of  data 

Summary of Contents for Accuvim II

Page 1: ......

Page 2: ......

Page 3: ...of Accuenergy The information contained in this document is believed to be accurate at the time of publication however Accuenergy assumes no responsibility for any errors which may appear here and res...

Page 4: ...rous Observe the information after the symbol to avoid possible injury or death Focus symbol avoid inadvertent operations which may lead to abnormal working of instrument even damage to the instrument...

Page 5: ...RJ45 Interface 8 2 4 Cable 9 2 5 Connection Method 9 Chapter 3 Function Description of Ethernet MODULE 11 3 1 Initializing Ethernet Module 12 3 2 Searching IP Address of Ethernet Module 22 3 3 Descri...

Page 6: ...s manual carefully before operating and setting the Acuvim II meter to avoid unnecessary trouble Chapter 1 helps you to understand the fundamental concept of Ethernet and application points of Etherne...

Page 7: ...1 Chapter 1 Introduction Ethernet Introduction Function Description...

Page 8: ...y standard Ethernet is the most current communication standard in LAN This standard defines the used type of cable and the used method of Signal processing in LAN 1 2 Function Description of Ethernet...

Page 9: ...Ethernet Modual and the default value of protocol port is 80 and the scope of protocol port is 6000 9999...

Page 10: ...Ethernet Modual...

Page 11: ...Chapter 2 Wiring and Connection Appearance and Dimensions Installation Method Definition of RJ45 Interface Cable Connection Method 5...

Page 12: ...In addition Ethernet module must be the first extended module linked to Acuvim II meter 2 1 Appearance and Dimensions Side View Top View NOTE The environment temperature and humidity should fulfill th...

Page 13: ...to Acuvim II meter by communication plug It can also be linked to other extended modules like IO modules 1 Insert the installation clips to the counterpart of Acuvim II meter and then press the Ether...

Page 14: ...RJ45 connector access Ethernet network The mechanical and electrical characteristics of connector are consistent with the requirements of IEC 603 7 Top View Script ID Content 1 TX Tranceive Data 2 TX...

Page 15: ...rd 2 5 Connection Method 1 Direct Connect Ethernet module use cross line standard 568A to connect to computes Users may refer to the third chapter Function description of Ethernet module for using Eth...

Page 16: ...10 Ethernet Modual...

Page 17: ...11 Chapter 3 Function Description Initializing Ethernet Module Searching IP Address of Ethernet Module Description of Modbus TCP protocol Browse Webpage and Set Parameters Mail Function...

Page 18: ...Module AXM Net default settings are IP Address 192 168 1 254 Subnet Mask 255 255 255 0 Gateway 192 168 1 1 Primary DNS Server 202 106 0 20 If you don t know the settings of module when power on for t...

Page 19: ...tting mode Device address page is the first page of Setting mode It shows the Modbus address of the device for several seconds and then the screen goes to Access Code page Press V A key go to the para...

Page 20: ...ion mode in the first setting page AUTO means that users configure module settings with DHCP protocol while MANU means that users configure module settings with manual setting Press V A key go to sett...

Page 21: ...e Wait until the reset is finished and find the new IP address in the following step Figure 3 5 d Set IP Address in the second setting page such as 192 169 1 100 as shown below Press V A key go to set...

Page 22: ...such as 255 255 255 0 Press V A key go to setting state Users may set parameter in the pointed area and cursor starts at the first digit bit After setting Subnet Mask completely press V A key to affi...

Page 23: ...2 169 1 1 Press V A key go to setting state Users may set parameter in the pointed area and cursor starts at the first digit bit After setting Gateway completely press V A key to affirm Again press P...

Page 24: ...state Users may set parameters in the pointed area and cursor starts at the first digit bit After setting DNS Primary Server completely press V A key to affirm Again press P key go to the sixth setti...

Page 25: ...ing state Users may set parameter in the pointed area and cursor starts at the first digit bit After setting DNS Secondary Server completely press V A key to affirm Again press P key go to the seventh...

Page 26: ...ted area and cursor starts at the first digit bit After setting Modbus TCP port completely press V A key to affirm Again press P key go to the eighth setting page for HTTP port Modbus TCP port s defau...

Page 27: ...ed range of port is 6000 9999 If the set port is not in range the set port will return default value Figure 3 12 k Set resetting mode in the ninth setting page Select RESET to reset module Select NO m...

Page 28: ...aneously to return menu selecting mode Users can do other operation 3 2 Searching IP Address of Ethernet Module Acuvim II tool software supports search function and Users use it to get IP address and...

Page 29: ...23 Ethernet Modual Figure 3 14 3 Tool software pop up Search Device s window and window display IP address and MAC address of module Figure 3 15...

Page 30: ...ng mode of Modbus TCP protocol Figure 3 16 1 Protocol 1 Data Frame Format MBAP Header Function Data 7x8 Bits 8 Bits Nx8 Bits Table 3 1 2 Modbus Application Header MBAP Header Field Modbus application...

Page 31: ...Data Field The data field is constructed using sets of two hexadecimal digits in the range of 00 to FF hexadecimal The data field of messages sent from a master to slave devices contains additional in...

Page 32: ...the meaning of each abbreviated word is Transaction identifier hi Transaction Identifier high byte Transaction identifier lo Transaction Identifier low byte Protocol identifier hi Protocol Identifier...

Page 33: ...er 00H 00H 00H 00H 00H 06H 01H Fun Data start reg hi Data start reg lo Data of regs hi Data of regs lo 01H 00H 00H 00H 02H Table 3 5 Read 2 Relays Status Query Message Response The Acuvim II response...

Page 34: ...m II and the start address is 0000H The following query is to read the 4 DIs Status of address 1 of Acuvim II Query Transaction identifier hi Transaction identifier lo Protocol identifier hi Protocol...

Page 35: ...identifier 00H 00H 00H 00H 00H 04H 01H Fun Byte count Data 02H 01H 0FH The content of the data is 7 6 5 4 3 2 1 0 0 0 0 0 1 1 1 1 MSB LSB Table 3 8 Read 4 DIs Response Message 3 Read Data Function Co...

Page 36: ...03H 0CH 07H D6H 00H 0CH 00H 12H 00H 0EH 00H 0FH 00H 14H Table 3 10 Read Time Response Message 4 Control Relay Function Code 05 Query The message forces a single Relay either on or off Any Relay that...

Page 37: ...elay Response Message 5 Preset Reset Multi Register Function Code 16 Query Function code 16 allows the user to modify the contents of a Multi Register The example below is a request to an Acuvim II ad...

Page 38: ...i Registers Response Message Users may refer to the fifth chapter Communication and get the details of Acuvim II When users use Moubus Tcp function you set best the Scan Interval of tool soft under 10...

Page 39: ...ink to get into webpage Figure 3 17 1 Index Webpage Users put IP address of module in Address of IE Browser and enter Index webpage Index webpage supplies three links to enter Data webpage or Settings...

Page 40: ...gs Webpage Press Settings link to enter settings webpage Figure 3 20 is flow chart for settings webpage First IE Browser enters Password webpage and it need check module password Initial password is 1...

Page 41: ...ng Mode Event Mode None Mode Select Content and Press Affirm Button Select Load Default Manner and Press Affirm Button Password Setting Webpage Complete Webpage Set New Password and Press Affirm Butto...

Page 42: ...Settings webpage It supports two network setting mode Manual or Auto Except network setting mode there are two port settings in Webpage One is HTTP port and the other is Modbus TCP port The default va...

Page 43: ...37 Ethernet Modual Figure 3 22 Figure 3 23 Configure network settings completely for Manual mode webpage Figure 3 23 Figure 3 24 configure network settings completely for Auto mode webpage...

Page 44: ...connection for these settings and the module may not send mail The value of Mail Sending Interval is interval time between two mails under Send mail for timing mode the default value is 1 hour the ran...

Page 45: ...ng mode webpage Send mail for timing mode is a timing manner according to Mail Sending Interval which sends mail content to Mail to mail box Under this mode mail content includes Real Time Metering En...

Page 46: ...s a manner of event triggered according to event type Alarm type SOE type which sends mail content to Mail to mail box Under this mode mail content includes Alarm Event SOE Event and users may select...

Page 47: ...ubject and Mail Sending Interval needn t be set repeatedly 4 Webpage Settings Webpage Figure 3 30 Webpage Settings webpage Users set the value of Device s Description according to meter type The defau...

Page 48: ...42 Ethernet Modual Figure 3 30 Figure 3 31 webpage settings set completely webpage Figure 3 31 5 Load Default Webpage Figure 3 32 Load Default webpage Figure 3 32...

Page 49: ...Figure 3 33 Load default successful webpage The network settings of module will renewed default value Figure 3 33 6 Password Setting Webpage Figure 3 34 Password Setting webpage Figure 3 34 6 12word...

Page 50: ...3 36 is flow chart of data webpage There are six kinds of data webpage They are Metering webpage Energy and Harmonics webpage and Max and Min 1 Max and Min 2 webpage Alarm Record webpage and SOE Reco...

Page 51: ...n parameters such as Volts AN I A and Watt Total Demand Max and Min 2 webpage includes the max and min data of parameters for Acuvim II There are twelve parameters such as Frequency Imbalance V and TH...

Page 52: ...rval which sends mail content to Mail to mail box The mail content includes Real Time Metering Energy and Harmonics Max and Min Send mail for event mode is a manner of event triggered according to eve...

Page 53: ...Appendix Appendix A Technical Data and Specifications Appendix B Ordering Information Appendix C Revision History 47...

Page 54: ...tal IEC 60068 2 30 Safety IEC 61010 1 Communication Port Physical Layer Standard RJ45 socket Protocol Modbus TCP SMTP HTTP Baud Rate 10M 100M auto adapted Suitable Condition Dimensions 90X55 6X22 mm W...

Page 55: ...49 Ethernet Modual Appendix 2 Ordering Information Type AXM NET...

Page 56: ...50 Ethernet Modual Appendix C Revision History Revision Date Description 1 0 20070915 1 01 20080718 Note User need to set the parameter of network...

Page 57: ......

Page 58: ......

Reviews: