1
Ethernet Modual
Detail of Ethernet module will be described in this chapter. It includes
how to set parameters of module, how to get IP address and Mac
address of module, content about Modbus/TCP protocol, how to visit
webs, and how to use mail function.
3.1 Initializing Ethernet Module
AXM-Net default settings are
IP Address (192.168.1.254);
Subnet Mask (255.255.255.0);
Gateway (192.168.1.1);
Primary DNS Server (202.106.0.20).
If you don’t know the settings of module when power on for the fist time,
you may use the panel of Acuvim II to get them and to configure them.
This procedure shows how to configure Ethernet module settings by
panel:
a) Press “H” key and “V/A” key simultaneously on Acuvim II will go to the
menu selecting mode. Cursor “Meter” flashes in this mode.