Accu-Steam™ G2 Electric Installation and Operators Manual
MP5018-1702
PAGE 26
MODE
LED Indicators
DISPLAY
NOTES
Off
All LED’s are off when
powered down.
Off when powered down.
When powered On, the
controller would FLASH
at a 1 Hz rate the current
set temperature for 5
seconds. After this period
the controller would go
to Warm Up / Cool Down
Mode.
To turn unit on: depress the
On/Off
key.
To turn off the unit, disable outputs, save the
current set point temperature (see details in
“Other Features”) and turn off the display:
press and hold the
On/Off
key for
approximately five seconds.
Warm Up / Cool
Down
Blinking LED
above the selected
temperature key (LED
1, 2 or 3). If default
condition then LED 1.
If Preset 2 is selected
then LED 3 If Preset 1
then LED 2
Actual temperature when
no keys depressed, or set
temperature of the
Preset/Manual key when
key
UP arrow key
Preset 1 key or
Preset 2 key
is
momentarily pressed.
Upon power-on or whenever another
temperature setting is made, the unit will
enter this mode and will exit this mode only
when the actual temperature has regulated.
Ready Mode
LED above the
selected key will be
ON
Default display and
alternate display options
will be determined
according to Parameter 2
as shown in Tables 10.21
and 10.22.
Once has regulated, the indicator LED above
the selected key will go to solid ON. .For
details on display operation, please refer to
Parameter 2 as shown in Tables 10.21 and
10.22.
Set Temperature
(On the fly)
All indicator LEDs
blinking
Set Point Value when user
Lock Mode is OFF, or “Loc”
when User Lock Out Mode
is ON
If the User Lock Out Mode is OFF, the set
temperature can be adjusted. To set the
temperature, press either the
UP arrow
key or the
DOWN arrow key
and hold
for approximately 3 seconds. The controller
will load and display Default Cook Temp
and enter set temperature mode. Press
the
UP arrow key
to increment or the
DOWN arrow key
to decrement from the
current temperature setting. Wait for five
seconds. If there are no other key presses,
the unit will auto start to the new setting.
Press the
On/Off
key to exit without
saving.
Select Preset
Temperature
Selected Preset
indicator LED blinking
Set Point Value
To select an alternate preset temperature, if in
Preset Temp 1
setting, press
Preset Temp 2 key
and hold for
approximately three seconds. If in
Preset Temp 2
setting, press
Preset
Temp 1
key and hold for approximately three
seconds.
DIGITAL TEMPERATURE CONTROL QUICK REFERENCE