Adjusting the stop position
The machine is equipped with two adjustable stop points. Proceed as follows before applying them. Bring
the machine to where you want it to stop. Check from the table according to the guide’s angle of inclination
where the stop points should be. Move the machine away and set the stop point temporarily using only one
screw and positioning it approximately in the centre of the slot. Then make the final adjustment by moving
the machine back and forwards until the required stop point is set. At this point the cam can be locked with
the second screw.
Fig. 57 – Cam mounting
Attention!
The limit switch end with a slotted hole must be set on the opposite side of the one
coming from the position of the machine.
Caution!
The stop cam may interfere with the guide fixing device.
“V” for cam perforating
Adjusting screw
Datum
Point
Origin of the
machine
Summary of Contents for RPSP
Page 1: ...Supra Linea Inclined Platform Lift Installation Manual INS RPSP EN 05 ...
Page 6: ...5 Installation Manual RPSP INS RPSP EN 05 Fig 2 General exploded view ...
Page 7: ...6 Installation Manual RPSP INS RPSP EN 05 Fig 3 Register exploded view ...
Page 8: ...7 Installation Manual RPSP INS RPSP EN 05 Fig 4 View of the guide ...
Page 9: ...8 Installation Manual RPSP INS RPSP EN 05 Fig 5 Machine body ...
Page 11: ...10 Installation Manual RPSP INS RPSP EN 05 Fig 7 Platform Fig 8 Lateral Motorized Flap SML ...
Page 12: ...11 Installation Manual RPSP INS RPSP EN 05 Fig 9 Frame crush proofing Fig 10 Anti impact ...
Page 14: ...13 Installation Manual RPSP INS RPSP EN 05 Fig 12 Three phase electrical motor connections ...
Page 57: ...56 Installation Manual RPSP INS RPSP EN 05 ...
Page 58: ...57 Installation Manual RPSP INS RPSP EN 05 ...
Page 60: ......