Installation and Operation Manual
Chapter 4 Configuration
ASMi-54 Ver. 1.0
Configuring for Operation
4-9
To configure the NTP client parameters:
1. Select
Main
Menu>Configuration>System.
The Configuration System screen appears (see
Figure 4-2
).
2. Select
Date and Time.
The Date and Time screen appears (see
Figure 4-13
). The parameters are
described in
Table 4-1
.
3. Press
<S> to save the changes.
ASMi-54
Main Menu > Configuration > System > Date and Time
Date
...(01-10-1949)
Time
...(00:00:01)
1 NTP Mode
> (Unicast Client)
2 GMT
> (0)
3 NTP Server IP Address
...(172.17.163.93)
4 NTP Update Interval (sec)
...(5)
5 Send Initiated NTP Request
ESC-Previous menu; !-Main menu; &-Exit
Figure 4-13. Date and Time Screen
Table 4-1. Date and Time Configuration Parameters
Parameter Possible
Values
Remarks
NTP Mode
Unicast Client
Disable
NTP request is sent to a specific IP address
Default: Disable
GMT
-12 ... 12
Offset from Greenwich Mean Time
Default: 0
NTP Server IP
Address
xxx.xxx.xxx.xxx
Default: 0.0.0.0
NTP Update
Interval (sec)
0 (disable)
1 ... 4294967295
Time (in seconds) between NTP requests
Default: 0 (disable)
Send Initiated
NTP Request
Each time this is pressed, an NTP request is sent regardless of the
NTP update interval.
Configuring Physical-Level Port Parameters
ASMi-54 has one or four Fast Ethernet interfaces and up to four SHDSL interface.
The Fast Ethernet and SHDSL configuration menus are accessed from the Physical
Layer menu.
Summary of Contents for RAD ASMi-54
Page 1: ...ASMi 54 G SHDSL bis Modem Version 1 0 INSTALLATION AND OPERATION MANUAL The Access Company ...
Page 2: ......
Page 120: ...Index Installation and Operation Manual I 4 ASMi 54 Ver 1 0 ...
Page 122: ......
Page 124: ......
Page 125: ......