80 Bays SAS to SAS/SATA JBOD Subsystem
User Manual
51
NOTE: After replacing the Power Supply Fan Module and turning on
the Power On/Off Switch of the PSFM, the Power Supply will not
power on immediately. The Fans in the PSFM will spin-up until the
RPM becomes stable. When Fan RPM is already stable, the JBOD
controller will then power on the Power Supply. This process takes
more or less 30 seconds. This safety measure helps prevent possible
Power Supply overheating when the Fans cannot work.
Appendix A Zoning Configurations
The JBOD subsystem features provide for zoning on the JBOD Controller Modules. This
allows the input ports on the JBOD Controller Modules to be assigned specifically to
particular drives in the subsystem.
The JBOD subsystem supports four different zoning modes: Zoning mode 0, Zoning
mode 1, Zoning mode 2 and Zoning mode 3.
A.1 Zoning mode 0: Default No Zoning
In this mode, all installed drives are available to all of the host ports on both JBOD
Controller Modules.
Steps:
1.
Used RS-232 Port (Phone jack to DB9) link SAS JBOD.
2.
In command line please type “phyzone off”, than press “Enter”.