80 Bays SAS to SAS/SATA JBOD Subsystem
44
User Manual
3.3 Preparing the JBOD and Connecting to RAID Subsystem
1.
Install the disk drives, if not yet installed. Refer to Section 2.6 Disk Drive
Installation for detailed information.
2.
Connect one end of SAS cable to the
SAS In Port
of the JBOD subsystem
enclosure and the other end to the
SAS Expansion Port
of the RAID subsystem
enclosure.
3.4 Preparing the JBOD and Connecting to SAS HBA in Host System
1.
Install the disk drives, if not yet installed. Refer to Section 2.6 Disk Drive
Installation for detailed information.
2.
Connect one end of SAS cable to the
SAS In Port
of the JBOD subsystem
enclosure and the other end to the SAS HBA on the Host system.
3.5 Powering On
1.
Plug in all the power cords into the AC Power Input Socket located at the PSFM.
NOTE: The subsystem is equipped with redundant, full range
power supplies with PFC (power factor correction). The system
will automatically select voltage.
2.
Turn on each Power On/Off Switch of the PSFM. The main switch button in the
front panel will still flashing blue.
NOTE: When the power cord connected from main power source is
inserted to the AC Power Input Socket, the Power Status LED
becomes
RED
. When the switch of the PSFM is turned on, the LED
still shows
RED
. After the main switch in front panel is turned on,
the LED turns
GREEN
, which means it is functioning normally.