background image

Chapter 2: Getting Started

Preparation

This scale is intended for indoor use.

The scale will function best when used in a stable, vibration-free, and level environment.

Do not use the scale near magnets or equipment that contains magnets. Avoid using the scale 

near equipment that creates strong electrical interference.

Avoid storing or using the scale in places with large temperature changes. Temperatures 

above 40C (104F) and below 15C (59F) may result in weighing inaccuracy.

Chapter 2: Getting Started                                                                                                                                  8

Summary of Contents for Cinco

Page 1: ...s in this operation manual apply to Acaia Cinco Scale You have purchased a quality precision weighing scale that requires handling with care Make sure to read through this operation manual prior to us...

Page 2: ...masses or weights used for calibration For more details please read Calibration Mode section in the operation manual CAUTION 1 Any modification made without the consent of the manufacturer will resul...

Page 3: ...Mode 2 Dual Display Mode 12 Mode 3 Auto Start Mode 13 Chapter 4 Calibration 13 Calibration mode 14 Chapter 5 Configuration 14 Enter settings 15 Auto Sleep Settings 15 Zero Tracking Setting 15 Key Soun...

Page 4: ...by step guides examples and other information Warning Incorrect handling of this product could possibly result in personal injury or physical damage Specifications Aprox Weight 70g Capacity 500g 17 63...

Page 5: ...g 300g d 0 02g for 300g 500g Work Time Up to 7 hours Starting Weight 1d Error Range 0 02g Chapter 1 Scale at a glance 5 Scale Back Micro B USB port Tare Key Scale Front Power Key LED Display Weighing...

Page 6: ...p reset timer Back While in Settings press to go back to Weighing Mode Default Setting Tare While in Weighing Mode Dual Display Mode Auto Start Mode press to perform tare operation Toggle units Long P...

Page 7: ...d An automotive cell phone charger with a USB port or a Micro USB cable A wall charger with an output of 5 volts and 1 amp is recommended The scale takes 1 2 hours to fully charge from an empty batter...

Page 8: ...vel environment Do not use the scale near magnets or equipment that contains magnets Avoid using the scale near equipment that creates strong electrical interference Avoid storing or using the scale i...

Page 9: ...s back panel for charging Note To avoid affecting the accuracy of the scale do not use the scale during charging Long press power button to turn on the scale It is highly recommended to calibrate the...

Page 10: ...1 There are two different weighing units in Weighing Mode gram and ounce 2 The readability is 0 01g for grams and 0 0005 oz for ounces Action Operation Turn On Scale Press and hold power button Turn...

Page 11: ...ng Mode gram and ounce 2 In gram units the display range is from 0 00 to 500 00 3 3 In ounce units the display range is from 0 0000 to 17 637 3 4 If the weight exceeds 500 00 grams the scale will disp...

Page 12: ...0000 with the timer on the left and the weight on the right in ounce units 3 The timer displays from 00 to 99 When the value is over 99 the timer will stop Mode Description 1 STEP 1 When placing more...

Page 13: ...able Disable Auto Start Mode please go to Chapter 5 Configuration Chapter 4 Calibration Calibration Mode 1 While the scale is in Weighing Mode and the weighing unit is in gram press T Button rapidly u...

Page 14: ...operation does not increase the scale capacity Setting Display Options Default Auto Switch Off SLEEP 5 10 20 30 60 Off 5 Zero Tracking trAcE 0 5d 1d 2d 3d Off 1d Key Sound bEEP On Off On Zero Range O...

Page 15: ...can also be configured from the Brewmaster Use this setting to turn the beeping sound on or off Zero Range Setting The Zero Range setting determines the range for which T Button executes zero operati...

Page 16: ...d Dual Display Mode Setting nodE_2 1 The default Dual Display Mode Setting is set to ON which means this mode is enabled 2 ON The Dual Display Mode is enabled 3 OFF The Dual Display Mode is disabled A...

Page 17: ...nitial weight exceeds the limit 250 of capacity 304 Please calibrate the scale in a stable environment free of vibration wind etc 904 Password error the default password is 0000 _H2O Water in the Powe...

Page 18: ...reserved No part of the operation manual may be reproduced processed duplicated or published in any form by photocopying microfilming reprinting or any other method in particular electronic means with...

Reviews: