13
UK
10 Notes on wiring
10.1 Alarm
centre
Terminal connector strip for tamper and alarm
zones.
COM A/T:
Connections for detector tampering
CCT 1…8:
Connections for alarm zones 1–8
Terminal connector strip for 12V DC power supply of
external equipment (e.g., detectors)
AUX:
+12V permanent voltage for detectors
0V:
0V ground
Terminal connector strip for loudspeaker, progr. outputs and
siren tampering.
TR:
Sabotage
inputs
+ / LS:
Contact for optional 16 Ohm
loudspeaker
OP1, OP2, OP3
:
Contact for Open Collector Transistor
output (e.g. as trigger signal of dialler)
Terminal strip for control units
12V:
12V+ permanent voltage
0V:
0V
ground
Data:
Databus
Clock:
Databus