46
UK
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
040 System Rearm
To change the property of the siren duration:
1. On the control unit, enter:
040
2. The LCD display shows: 040:Rearm=Never
3. Via the keypad, select from the following items
and press:
0
Rearm=Never
If an alarm is triggered, the alarm is
sounded until the defined alarm time of
the external signaller. If a second
sensor reports another alarm following
expiry of the defined alarm time, no
second alarm is triggered.
1-4
Rearm 1-4/Always
If an alarm is triggered, the alarm is
sounded until the defined alarm time of
the external signaller. The alarm centre
rearms itself once, twice, three times or
always, depending on the value
entered. A new alarm reports triggers a
new alarm.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
041 Siren delay
Proceed as follows to change the property of the siren
delay:
1. On the control unit, enter:
041
2. The LCD display shows: 041:Bell Dly=0
3. Via the keypad, select from the following items
and press:
0
Bell Dly=0
After an alarm is triggered, a local alarm
is started without delay.
1
Bell Dly=1.5
After an alarm is triggered, a local alarm
is activated after a delay of 1.5 minutes.
2
Bell Dly=3
After an alarm is triggered, a local alarm
is activated after a delay of 3 minutes.
3
Bell Dly=5
After an alarm is triggered, a local alarm
is activated after a delay of 5 minutes.
4
Bell Dly=10
After an alarm is triggered, a local alarm
is activated after a delay of 10 minutes.
5
Bell Dly=15
After an alarm is triggered, a local alarm
is activated after a delay of 15 minutes.
6
Bell Dly=20
After an alarm is triggered, a local alarm
is activated after a delay of 20 minutes.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
Summary of Contents for Terxon SX AZ4000
Page 10: ...10 D 8 bersicht der Geh usekomponenten 1 2 3 4 6 5 7 8...
Page 76: ...76 D...
Page 86: ...10 UK 8 Overview of housing components 1 2 3 4 6 5 7 8...
Page 148: ...4 FR 16 Fiche technique 72 17 D pannage 73 18 Index 74 19 Plan du syst me 75...
Page 154: ...10 FR 8 Vue d ensemble des composants du bo tier 1 2 3 5 7 8 4...
Page 220: ...76 FR...
Page 230: ...10 NL 8 Overzicht van de componenten van het huis NL 1 2 3 4 6 5 7 8...
Page 294: ...74 NL...