43
UK
028 Status display
Proceed as follows to change the property of the status
display:
1. On the control unit, enter:
028
2. The LCD display shows: 028:Status OFF
3. Via the keypad, select from the following items
and press:
0
Status OFF
The display is permanently on. The
system always shows whether the
alarm centre is activated or deactivated.
1
Status ON
The status display of the alarm centre
remains active for 180 seconds after
entry of the user code, and then
changes to date and time display.
2
Status Code
30 seconds after each event, the
display changes back to date and time
display. Note that the LEDs also light
for 30 seconds.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
029 Entry alarm delay
Proceed as follows to change the property of the entry
alarm delay:
1. On the control unit, enter:
029
2. The LCD display shows: 029:Delay OFF
3. Via the keypad, select from the following items
and press:
0
Delay OFF
The alarm centre generates an
immediate alarm if the user deviates
from the specified entry route.
1
Delay ON
The alarm centre extends the entry
delay by 30 seconds if the user
deviates from the specified entry route.
An internal alarm is triggered to inform
the user that he/she has made a
mistake. If the user code is entered
within the delay time, a local alarm is
prevented and the alarm centre is reset.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
030 Panic silent
To change the property of the silent panic alarm:
1. On the control unit, enter:
030
2. The LCD display shows: 030:PA audible
3. Via the keypad, select from the following items
and press:
0
PA audible
When a panic alarm is triggered, the
alarm centre generates a local alarm.
1
PA silent
When a panic alarm is triggered, the
alarm centre generates no local alarm.
The alarm is issued only via the relay
contacts and via the optional dialler.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
Summary of Contents for Terxon SX AZ4000
Page 10: ...10 D 8 bersicht der Geh usekomponenten 1 2 3 4 6 5 7 8...
Page 76: ...76 D...
Page 86: ...10 UK 8 Overview of housing components 1 2 3 4 6 5 7 8...
Page 148: ...4 FR 16 Fiche technique 72 17 D pannage 73 18 Index 74 19 Plan du syst me 75...
Page 154: ...10 FR 8 Vue d ensemble des composants du bo tier 1 2 3 5 7 8 4...
Page 220: ...76 FR...
Page 230: ...10 NL 8 Overzicht van de componenten van het huis NL 1 2 3 4 6 5 7 8...
Page 294: ...74 NL...