60
UK
182 Last output for settling time
This time sets a delay in the alarm report for detectors in
the exit area. The sirens are switched off during this time
and the alarm centre ignores the alarms.
To change the settings:
1. On the control unit, enter:
182
2. The LCD display shows: 182:Settling 07
3. Via the keypad, select from the following items
and press:
07-12
Settling 07-12
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
183 Change display
To change the settings:
1. On the control unit, enter:
183
2. The LCD display shows: 183: Terxon SX
3. Use the keyboard to change the display. Use the
keyboard in the same way as when assigning the
zone names.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
184 Fire signal transmitter
To change the settings:
1. On the control unit, enter:
184
2. The LCD display shows: 184:FirePulseOFF
3. Via the keypad, select from the following items
and press:
0
FirePulseOFF
Normal 2-tone fire alarm
1
FirePulseON
Transmits a pulse signal to the outputs
connected as „Siren“ (81-83=00)
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
185 Key switch auto reset
To change the settings:
1. On the control unit, enter:
185
2. The LCD display shows: 185:KsAutoRstOFF
3. Via the keypad, select from the following items
and press:
0
KsAutoRstOFF
The user must manually reset any
triggered zones.
1
KsAutoRstON
The system automatically resets zone
types KM or KF when the user activates
using the key switch.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
201 Prog. entry delay time 1
Define entry delay time 25.40 mm seconds. Proceed as
follows:
1. On the control unit, enter:
201
2. The LCD display shows: 201: Entry 1=20
3. Via the keypad, enter the entry delay time.
4. Confirm your input by pressing.
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
Summary of Contents for Terxon SX AZ4000
Page 10: ...10 D 8 bersicht der Geh usekomponenten 1 2 3 4 6 5 7 8...
Page 76: ...76 D...
Page 86: ...10 UK 8 Overview of housing components 1 2 3 4 6 5 7 8...
Page 148: ...4 FR 16 Fiche technique 72 17 D pannage 73 18 Index 74 19 Plan du syst me 75...
Page 154: ...10 FR 8 Vue d ensemble des composants du bo tier 1 2 3 5 7 8 4...
Page 220: ...76 FR...
Page 230: ...10 NL 8 Overzicht van de componenten van het huis NL 1 2 3 4 6 5 7 8...
Page 294: ...74 NL...