background image

 

English 

1.  Introduction 

 

Dear customer, 
We are pleased that you have chosen our product and thank you for your trust! You 
made a good choice. 
This Magnetic contact (hereinafter referred to as the "device") has been developed and 
manufactured  with  the  utmost  care.  Please  read  these  operating  instructions 
completely and observe all operating and safety instructions, as this ensures the best 
possible  handling  of  the  device.  This  document  is  an  installation  and  maintenance 
manual. 
 
All contained company names and product designations are trademarks of the 
respective owners. All rights reserved. 
If you have any questions, please contact your specialist installer or specialist trade 
partner! 
 

1.1.  Declaration of Conformity 

ABUS Security-Center hereby declares that the enclosed product comply with 
the requirements of the following directives 

 

RED  Directive  (2014/53/EU),  EMC  Directive  (2014/30/EU),  Low  Voltage  Directive 
(2014/35/EU)  and  RoHS  Directive  (2011/65/EU).  The  full  EU  Declaration  of 
Conformity text can be found at:  

 

www.abus.com/product/SHMK10000

 

 

It can also be obtained at the following adress: 

ABUS Security-Center GmbH & Co. KG, 

Linker Kreuthweg 5, 86444 Affing, GERMANY 

 

1.2.  Disclaimer of Liability 

These operating instructions have been prepared with the greatest care. Should you 
nevertheless notice omissions or inaccuracies, please inform us in writing at the above 
address. 

Your rights are limited to the repair or replacement of this product as delivered. ABUS 
Security  Center  assumes  no  liability  for  any  special,  incidental  or  consequential 
damages, including but not limited to loss of revenue, loss of profit, restrictions in the 
use  of  the  software,  loss  or  recovery  of  data,  costs  for  replacement  equipment, 
downtime, property damage and claims of third parties, as a result of and in connection 
with  the  use  of  the  software.a.  warranty,  contractual,  legal  or  claims  for  damages 
notwithstanding  other  limited  or  implied  warranty  provisions  or  in  the  event  that  the 
limited warranty does not apply, the scope of liability of ABUS Security Center is limited 
to the purchase price of the product. 

The contents of this manual are subject to change without notice. 

© ABUS Security-Center GmbH & Co. KG, 09/2018 

 

Summary of Contents for SHMK10000

Page 1: ...ABUS Z Wave Magnetic contact Important information and FAQs about this product and other products can be found on the website www abus com Version 1 0 Original operating instructions in English Keep for future use ...

Page 2: ... disposal 5 2 7 Cleaning 5 2 8 Information on device disposal 5 3 Product introduction 6 3 1 Scope of delivery 6 3 2 Device features 6 3 3 Operating principle 6 3 3 Performance features 7 3 4 Use in systems of different manufacturers 7 4 Overview of functions 7 4 1 Inclusion Add Device 7 4 2 Mounting Installation 8 4 3 Exclusion Remove Device 9 4 4 Reset Factory Reset 10 5 Advanced Z Wave Paramete...

Page 3: ...an be found at www abus com product SHMK10000 It can also be obtained at the following adress ABUS Security Center GmbH Co KG Linker Kreuthweg 5 86444 Affing GERMANY 1 2 Disclaimer of Liability These operating instructions have been prepared with the greatest care Should you nevertheless notice omissions or inaccuracies please inform us in writing at the above address Your rights are limited to th...

Page 4: ...agnetic fields e g loudspeakers no naked flames e g lit candles are placed on or next to the device sprayed or dripping water is prevented from coming into contact with interior devices and caustic fluids are avoided the device is not operated in the vicinity of water in particular the device should never be submerged do not place objects containing fluids e g vases or drinks on or near the device...

Page 5: ...s of mercury cadmium or lead which exceed the restrictions set by the EU Directive 2006 66 EG If batteries are not disposed of properly these substances can cause harm to human health or the environment 2 7 Cleaning Dusty devices must be cleaned You can clean dust from the air vents using a vacuum cleaner or compressed air If necessary you can remove the dust with a brush You can clean the surface...

Page 6: ...nt 1 Device 2 Magnet 3 Status LED Serves as status display for various processes 4 Tamper Button For inclusion exclusion of the detector in a Z Wave gateway factory reset and tamper alarm 5 Battery case For CR2 Batterien 3V DC 3 3 Operating principle The SHMK10000 was developed for use in home automation systems that use the Z Wave wireless standard The sensor enables the monitoring of windows and...

Page 7: ...detects tampering when the housing is opened has a battery empty warning function was developed for indoor installation 3 4 Use in systems of different manufacturers Communication is via the Z Wave EU frequency 868 42 Mhz You can integrate the device into any Z Wave network with a certified Z Wave gateway regardless of manufacturer All non battery powered nodes in the network act as repeater to in...

Page 8: ... mounting position in advance The magnet should be mounted no more than 15 mm from the sensor Note Do not mount the detector on or near metal surfaces in close proximity 1m to gas water and power lines near electrical devices e g PC copier or other transmitters Installation site Optimum mounting location for the door window contact is the upper corner of your window or door frame B Remove the adhe...

Page 9: ...k the Remove button in your Z Wave App and follow the further instructions B Press the Tamper button 3 times within 1 5 seconds and the Status LED on the base unit front will flash 3 times The App will show if the Remove device process was successful and the Status LED on device will flash 6 times Repeat the exclusion process from step A if it was not successful ...

Page 10: ...ering a sensor When this event occurs a control command usually a BASIC SET is sent to all devices stored in an association group The magnetic contact supports the following association group Group Number Maximum Devices Transmitted Content Group 1 0x05 Lifeline association group Include command classe Battery report Notification report and Device Reset Locally notification Binary report Group 2 0...

Page 11: ...erlevel Version 1 10 Battery Version 1 11 Security 2 Version 1 12 Supervision Version 1 13 Wake Up Version 2 6 Technical Specifications Parameters Unit SHMK10000 Dimensions mm 72 x 21 x 26 Sensor 35 x 11 x 13 Magnet Weight g 45 Operating Temperature C 0 40 Max Humidity 95 IP Class 20 Radio frequency MHz 868 42 Z Wave PLUS Europe Modulation FSK GFSK Transmission power db 4 5 Power supply 3 V DC Bat...

Page 12: ...12 English Security S2 Classes Yes Z Wave Chip Generation 500 Z Wave Sensor Typ Open Closed Binary Zwave library type Routing Slave Device Type Role type Notification sensor Reporting sleeping slave ...

Reviews: