Abus SHMK10000 Manual Download Page 10

 

10 

English 

4.4.  Reset (Factory-Reset)  

 
 

1. Press the Tamper-button 3 times within 1.5 
Seconds 
2.  The  device  is  now  restored  to  factory 
settings 

 
Note: 

 

1, This procedure should only be used if the 
primary gateway is not capable of acting.  
2,  If  the  multi-sensor  is  set  to  the  factory 
setting, the status is set to "not included", the 
association 

settings 

and 

possible 

configurations are reset to default. 
 
 
 

 

5.  Advanced Z-Wave Parameter 

 

5.1.  Association Group Information 

Z-Wave devices  can control other devices  directly.  This direct  control is called in  Z-
Wave association. For this purpose, the device ID of the device to be controlled must 
be stored in the controlling devices. This is done in so-called association groups. An 
association group is always linked to an event in the controlling device (pressing a key 
or triggering a sensor). When this event occurs, a control command - usually a BASIC 
SET - is sent to all devices stored in an association group. 

 

The magnetic contact supports the following association group: 

 

Group 
Number

 

Maximum 
Devices

 

Transmitted Content

 

Group 1 

0x05 

Lifeline  association  group  Include  command  classe: 
Battery report, Notification report, and Device Reset Locally 
notification, Binary report. 

Group 2 

0x05 

Root  Device  group(Binary  Sensor)  Binary  Sensor 
Command  Class:Compatible  with  300  series  1-Binary 
Sensor reports status of open or close door via Lifeline. 2-
When  the  sensor  detects  status  change  between  close 
door and open door, the device will be triggered. 

Group 3 

0x05 

Root  Device  group(Binary  Sensor)  Binary  Sensor 
Command Class:Compatible with 300 series  

1-Binary Sensor reports the removed status of door sensor.  

2-When  the  sensor  detects  status  change  of  tamper,  the 
device will be triggered. 

Group 4 

0x05 

Root Device group(Notification)  

1-Notification report open door or close status via Lifeline.  

Summary of Contents for SHMK10000

Page 1: ...ABUS Z Wave Magnetic contact Important information and FAQs about this product and other products can be found on the website www abus com Version 1 0 Original operating instructions in English Keep for future use ...

Page 2: ... disposal 5 2 7 Cleaning 5 2 8 Information on device disposal 5 3 Product introduction 6 3 1 Scope of delivery 6 3 2 Device features 6 3 3 Operating principle 6 3 3 Performance features 7 3 4 Use in systems of different manufacturers 7 4 Overview of functions 7 4 1 Inclusion Add Device 7 4 2 Mounting Installation 8 4 3 Exclusion Remove Device 9 4 4 Reset Factory Reset 10 5 Advanced Z Wave Paramete...

Page 3: ...an be found at www abus com product SHMK10000 It can also be obtained at the following adress ABUS Security Center GmbH Co KG Linker Kreuthweg 5 86444 Affing GERMANY 1 2 Disclaimer of Liability These operating instructions have been prepared with the greatest care Should you nevertheless notice omissions or inaccuracies please inform us in writing at the above address Your rights are limited to th...

Page 4: ...agnetic fields e g loudspeakers no naked flames e g lit candles are placed on or next to the device sprayed or dripping water is prevented from coming into contact with interior devices and caustic fluids are avoided the device is not operated in the vicinity of water in particular the device should never be submerged do not place objects containing fluids e g vases or drinks on or near the device...

Page 5: ...s of mercury cadmium or lead which exceed the restrictions set by the EU Directive 2006 66 EG If batteries are not disposed of properly these substances can cause harm to human health or the environment 2 7 Cleaning Dusty devices must be cleaned You can clean dust from the air vents using a vacuum cleaner or compressed air If necessary you can remove the dust with a brush You can clean the surface...

Page 6: ...nt 1 Device 2 Magnet 3 Status LED Serves as status display for various processes 4 Tamper Button For inclusion exclusion of the detector in a Z Wave gateway factory reset and tamper alarm 5 Battery case For CR2 Batterien 3V DC 3 3 Operating principle The SHMK10000 was developed for use in home automation systems that use the Z Wave wireless standard The sensor enables the monitoring of windows and...

Page 7: ...detects tampering when the housing is opened has a battery empty warning function was developed for indoor installation 3 4 Use in systems of different manufacturers Communication is via the Z Wave EU frequency 868 42 Mhz You can integrate the device into any Z Wave network with a certified Z Wave gateway regardless of manufacturer All non battery powered nodes in the network act as repeater to in...

Page 8: ... mounting position in advance The magnet should be mounted no more than 15 mm from the sensor Note Do not mount the detector on or near metal surfaces in close proximity 1m to gas water and power lines near electrical devices e g PC copier or other transmitters Installation site Optimum mounting location for the door window contact is the upper corner of your window or door frame B Remove the adhe...

Page 9: ...k the Remove button in your Z Wave App and follow the further instructions B Press the Tamper button 3 times within 1 5 seconds and the Status LED on the base unit front will flash 3 times The App will show if the Remove device process was successful and the Status LED on device will flash 6 times Repeat the exclusion process from step A if it was not successful ...

Page 10: ...ering a sensor When this event occurs a control command usually a BASIC SET is sent to all devices stored in an association group The magnetic contact supports the following association group Group Number Maximum Devices Transmitted Content Group 1 0x05 Lifeline association group Include command classe Battery report Notification report and Device Reset Locally notification Binary report Group 2 0...

Page 11: ...erlevel Version 1 10 Battery Version 1 11 Security 2 Version 1 12 Supervision Version 1 13 Wake Up Version 2 6 Technical Specifications Parameters Unit SHMK10000 Dimensions mm 72 x 21 x 26 Sensor 35 x 11 x 13 Magnet Weight g 45 Operating Temperature C 0 40 Max Humidity 95 IP Class 20 Radio frequency MHz 868 42 Z Wave PLUS Europe Modulation FSK GFSK Transmission power db 4 5 Power supply 3 V DC Bat...

Page 12: ...12 English Security S2 Classes Yes Z Wave Chip Generation 500 Z Wave Sensor Typ Open Closed Binary Zwave library type Routing Slave Device Type Role type Notification sensor Reporting sleeping slave ...

Reviews: