Configuration
104
Name/function
Explanation (checkbox)
Force Set
A user can be permitted to arm the alarm panel using the remote control even if one
or more zones are not working or are open.
Note
If Force Set is enabled, the system is no longer compliant with EN 50131.
Dropdown selection field for:
•
Off
•
The user cannot force the system to arm with the remote control even if
the corresponding zones have been given attribute "Force Set".
Confirm
•
The user can force the system to arm with the remote control. To do so,
proceed as follows:
1. The user presses the "arm" button on the remote control.
2. The system does not start arming.
3. The user presses the same button on the remote control again to confirm
that the system should arm.
•
On
•
The user only has to press the corresponding button on the remote control
once to start the arming process.
Note
With the "Confirm" and "On" options, the user is also permitted to arm the system
with the remote control even if it would need to be reset after an alarm.
Remote Unset Full Set
Select whether
armed
partitions can only be disarmed using the
remote control
when the delay time has been started beforehand ("Final Door" zone is triggered).
Dropdown selection field for:
•
Always
•
The user can always disarm the possible partitions without the entry time
being started first.
•
During entry time
•
The user must first open a "Final Door" zone. This starts the entry delay.
The user can now disarm the possible partitions.
•
Partitions for which no entry delay has started remain armed.
Summary of Contents for SECVEST
Page 1: ...I n s t a l l e r m a n u a l...
Page 3: ...Contents 3...
Page 12: ...Device overview 12 International key assignment...
Page 14: ...Device overview 14...
Page 28: ......
Page 143: ...Configuration 143 Contacts Up to 12 recipients can be defined here to whom messages are sent...
Page 169: ...Index 169...
Page 170: ...Index 170...