Configuration
81
Name/function
Explanation
Siren Delay
Time for the delay duration of the siren(s).
The siren delay can be set to a value between 0 and 10 min.
When an alarm has been triggered the alarm panel waits until this time has expired
before it activates the sirens.
Note
The siren delay only goes into effect when the alarm response includes comms.
The siren delay does not go into effect when a comms fault occurs.
The siren delay does not go into effect when "Installer Mode->System
->Confirmation->Confirmation Mode->DD243 or BS8243" and "Installer Mode-
>System->Confirmation->Siren On ->Unconfirm" are set.
If sounders (or just control devices?) are assigned to multiple partitions, the alarm
panel uses the shortest siren delay set for the partitions in question.
Siren time ext. [min]
Time for the duration of the external siren(s) in minutes.
The siren time can be set to a value between 0 and 15 min.
If sounders (or just control devices?) are assigned to multiple partitions, the alarm
panel uses the longest siren time set for the partitions in question.
The time that the sounders are active for may also be extended by the longest of
the siren delays that the assigned partitions possess.
Pt.Set Final Exit
This option controls how a "Final Door" zone is handled when the system is
internally armed.
Final Door
•
Every zone in this partition with type "Final Door" and the attribute
"Part Set" continues to function as a "Final Door" zone.
Normal Alarm
•
Every zone in this partition with type "Final Door" and the attribute
"Part Set" functions as a "Normal Alarm" zone.
Summary of Contents for SECVEST
Page 1: ...I n s t a l l e r m a n u a l...
Page 3: ...Contents 3...
Page 12: ...Device overview 12 International key assignment...
Page 14: ...Device overview 14...
Page 28: ......
Page 143: ...Configuration 143 Contacts Up to 12 recipients can be defined here to whom messages are sent...
Page 169: ...Index 169...
Page 170: ...Index 170...