Configuration
141
Name/function
Explanation (checkbox)
Ethernet Line
Fault Delay
Time in seconds until the alarm system responds to a fault in the internet connection.
PSTN Line
Fault Delay
Time in seconds until the alarm system responds to a fault in the telephone connection.
GSM Line
Fault Delay
(only when GSM module
is used)
Time in seconds until the alarm system responds to a fault in the GSM connection.
GSM Omit Digit
(only when GSM module
is used)
Activated
If activated, the first digit of the saved telephone number in the phone book is not
selected with the rest of the number for a GSM connection.
•
If you want to make calls from a telephone of a private branch exchange into the
public telephone network, you must first dial what is known as the exchange
access code (code for an outside line) before you dial the telephone number.
•
In this case the exchange access code must be entered as the first digit in the
phone book on the alarm panel.
•
This is followed by the actual destination telephone number.
•
The exchange access code is available from the administrator of the private
branch exchange or in the instructions of the private branch exchange.
•
It is usually the number "0"; in the UK it is usually the number "9".
•
Format of the telephone number: "0 0123 4567890".
•
The alarm panel can therefore also be connected to an analogue extension of
a private branch exchange.
•
This extension does not necessarily have to be set up for automatic outside
line dialling.
Deactivated
On a private branch exchange, if you are using an extension that is programmed
for automatic outside dialling, or if you are using a regular analogue telephone
connection, select "Deactivated".
The setting "GSM Omit Digit=Activated" affects numbers to dial for:
•
ARC reporting
•
Social Care
•
Speech Dialler
SMS messages are normally sent only via GSM. The normal destination numbers
are saved in the phone book:
•
Format of the telephone number: "0123 4567890".
•
With a private branch exchange, the alarm panel is connected to an analogue
extension without automatic outside line dialling.
•
If you want to implement SMS dispatch that starts on the analogue connection of
the alarm system, then under
•
Installer Mode
Communications
SMS
PSTN SMS
Service Centre Tel.
•
Configure the exchange access code before the actual service centre telephone
number.
•
Format of the telephone number: "0 0123 4567890".
Summary of Contents for SECVEST
Page 1: ...I n s t a l l e r m a n u a l...
Page 3: ...Contents 3...
Page 12: ...Device overview 12 International key assignment...
Page 14: ...Device overview 14...
Page 28: ......
Page 143: ...Configuration 143 Contacts Up to 12 recipients can be defined here to whom messages are sent...
Page 169: ...Index 169...
Page 170: ...Index 170...