Installation, Operating and Maintenance Instructions (Original Instructions)
ABS submersible sewage pump XFP 80C - 201G
Symbols and notices used in this booklet:
Presence of dangerous voltage.
Non-compliance may result in personal injury.
Hot surface - danger of burn injury.
Danger of an explosion occurring.
ATTENTION!
Non-observance may result in damage to the unit or negatively affect its performance.
NOTE:
Important information for particular attention.
1 Application
areas
The following guidelines must be observed when setting the lowest switch off point for XFP pumps:
When switching on and operating the pump, the hydraulic section of dry installation pumps must always be
fi lled with water.
The minimum submergence allowed for specifi c pumps can be found on the dimension installation sheets
available from your local ABS representative.
XFP pumps have been designed for economic and reliable pumping in commercial, industrial and municipal
installations and are suitable for pumping of the following liquids:
clear and wastewater, and for sewage containing solids and fi brous material
faecal matter
In combination with the ABS automatic coupling system, the below ground level wet installation is a particularly
economical and environmentally friendly solution. The pumps are also suitable for horizontal or vertical dry
installation (except XFP 80E-CB1-PE125/2 and XFP 81E-VX-PE125/2, 60 Hz).
The regulations of DIN 1986 as well as local regulations should be observed when installing the pumps.
ATTENTION!
The maximum allowable temperature of the medium pumped is 40 °C
1.1 Explosion-proof
approvals
Explosion-proof as standard, in accordance with international standards Ex d IIB T4, ATEX 94/9/EC and FM (60
Hz US).
2 Safety
The general and specifi c health and safety guidelines are described in detail in the ABS Products Safety
Instructions booklet. If anything is not clear or you have any questions as to safety make certain to contact the
manufacturer ABS.
2.1
Use of explosion-proof pumps in explosive zones.
1.
Explosion-proof submersible pumps may only be operated with the thermal sensing system connected.
2.
If ball type fl oat switches are used, these must be connected to an intrinsically safe electrical circuit
“Protection type EX (i)” in accordance with VDE 0165.
3.
Dismantling and repair of submersible explosion-proof motors may only be carried out by approved
personnel in specially approved work shops.
4.
In the event that the pump is to be operated in explosive atmospheres using a variable speed drive,
please contact your local ABS representative for technical advice regarding the various Approvals and
Standards concerning thermal overload protection.
•
•
•
•