OPERATION
4
Control Panel
1. Timers
On top of the control panel, there are two timers: Timer I is for slow speed;
Timer II is for fast speed. Each timer has three digits.
The unit of A and B are minutes and C is 10 seconds, (for example: 0.1 is
10 seconds, 0.2 is 20 seconds.)
The timers are set by and buttons. Press button to
increase the time, the maximum set time is 20 minutes. After 20 minutes,
the timer starts from 0 minutes again. Press button for the opposite
operation.
When the spiral mixer is switched ON, timers will show the set time. The
timer will only work when mixer is in AUTO mode. The timer will start
automatically when the (ON) button is pressed. The slow speed timer will
run first and then the fast speed timer second, the mixer stops until timer
reaches 0 minute.
When the spiral mixer safety guard is lifted, the timer will stop with the mixer
and resume when the guard is lowed down and the ON button is pressed.
When the OFF button is pressed, the timers will return to the set time.