background image

TASCAM  Model 24

 1

                              Model 24

Checking the firmware version

Confirm the firmware version of your Model 24 before conducting a firmware update.

1. 

Turn the main unit on.

2. 

Press the MENU button to open the 

MENU

 Screen.

3. 

On the 

SYSTEM

 Screen, select 

INFORMATION

 to open the 

Information Screen.

4. 

Turn the MULTI JOG dial to open the 

FIRMWARE

 screen.

5. 

Check the 

VERSION

 (system firmware version) on this screen.

Updating is not necessary if the 

VERSION

 shown here is the 

same or newer than the firmware version you intend to use 

for the update.

NOTE

 

i

The screen shown above is an example. The actual appear-

ance will differ.

 

i

For details, see the “FIRMWARE screen” section of Chapter “8 – 

Settings and Information” in the Model 24 Owners Manual.

Firmware update procedures

1. 

Download the latest firmware from the TEAC Global Site 

(http://teac-global.com/).
Decompress the downloaded file if it is in ZIP format or 

another compressed file type.

2. 

Confirm that an SD card is loaded in the unit, turn the unit 

on and connect it to the computer using a commercial-

ly-available USB cable (Type-A - Type-B).

ATTENTION

The unit should be connected directly to the computer, not 

through a USB hub. Moreover, noise could be picked up if the 

cable is too long.

3. 

On the

MENU

 Screen, select 

STORAGE

 to open the 

STORAGE

 

Screen.

4. 

To connect with the computer, press the F4 

 button.

The unit enters USB storage mode and connects with the 

computer.

5. 

This unit appears on the computer as an external drive 

named “

TASCAM_M

” (if the card was formatted by this unit).

Copy the downloaded firmware to the “

UTILITY

” folder on 

TASCAM_M

”.

NOTE

The Model 24 firmware update file will have a name like 

Model24_XXXX.XXX

”.

6. 

After copying, use the proper procedures for the computer 

to unmount the unit.
See the computer’s operation manual for instructions about 

how to unmount an external volume.
Press the F1 

 button to return to the Meter Screen. 

Then, turn the unit off.

7. 

Turn the unit on while pressing the 

8

 and 

m

 buttons.

 

This will start the unit in update mode, and the update file 

will appear on the display.

ATTENTION

 

i

If this screen does not appear, turn the power off once, and 

turn the unit on again while pressing the 

8

 and 

m

 but-

tons. Keep pressing the 

8

 and 

m

 buttons until this screen 

appears.

 

i

If the firmware was copied to the “

UTILITY

” folder from a Mac, 

in addition to the firmware itself, another file with “

._

” before 

the firmware name will also appear. Select the file without “

._

” 

at the beginning.

NOTE

 

i

This screen shows a list of firmware update files in the “

UTIL-

ITY

” folder in the unit. The firmware copied in step 5 above 

should also be shown. “

No Update File

” is shown if the 

folder does not contain an update file.

 

i

The screen shown above is an example. The actual appear-

ance will differ.

8. 

Turn the MULTI JOG dial to select the firmware, and press 

the MULTI JOG dial. The screen shown below will appear.

The number of the current version is shown on the left and 

the update version is shown on the right.

NOTE

The screen shown above is an example. The actual appear-

ance will differ.

1218.MA-2830A

Reviews: