6
3 GENERAL
INFORMATION
Technical data
Measures
• 721 (L) x 85 (H) x 107 (W) mm
• Weight 9 kg
• Supply voltage 100/230 VAC (±10 %) 50...60 Hz
• Rated output 120 W
• Enclosure class IP20
Temperature range
• Storage -20...50 °C (in dry premises)
• Operation -15...50 °C (in dry premises)
• The automatic swing door operator must not be installed in applications where it is subjected to water or
snow
Interfaces
• Voltage output 24 VDC, stabilized, 500 mA (max 800 mA for 3 seconds)
• Potential free relay output
0,8 A @ 30VDC resistive load
0,3 A @ 30VDC inductive load
Door closer according EN1154:
Features
• Easy to install
• Normal door closer function when the power is switched off or templed
• Push&Go as a standard feature
• Prepull before opening
• Adjustable hold open time 0...60 s or sequential use
• Fire detector connection
• Lock control relay with NO/NC contacts
• Secondary DC inlet for power back up (24 VDC (±15 %), min. 5A)
• Maximum opening angles:
With
standard
arm
110°
With sliding arm (on the opening side) 100°
With sliding arm (on the closing side) 100°
Class
Standard arm
Sliding arm
Closing torque
Door mass [kg]
/ width [mm]
Door mass [kg]
/ width [mm]
[Nm]
(0-4°)
1
20 / 750
9
2
40 / 850
13
3
60 / 950
60 / 950
18
4
80 / 1100
80 / 1100
26
5
100 / 1250
37
6
120 / 1400
54