27
14 MAINTENANCE
Door operators require periodic maintenance.
Only trained personel are equiped to work on
ABLOY
®
DA
products.
Door leaf is moving sensitively and locking works well.
Regular annual services are made:
- Under 100 openings per day; service once a year
- 100 ... 500 openings per day; service two times a year
- Over 500 openings per day; service 3...4 times a year
Inspections made in service:
- Fixing of the operator and arm
- Clearance of the clutch (see p.29)
- Function and adjustments of impulse and safety devices
- Programming and adjustments of the operator
- Movement of the door, taught door positions
13 SELF DIAGNOSTICS (SAFETYSENSOR-UNIT)
A B
D
C
Indication
Possible fault
Corrective user interventions in de
fi
ned order
A
lit
Normal state of safetysensor closing side
C
lit
Normal state of safetysensor opening side
B
lit
Closing side safetysensor alert
1. Check sensor
fi
eld for obstacles
2. Check the condition of safety sensor cables.
D
lit
Opening side safetysensor alert
1. Check sensor
fi
eld for obstacles
2. Check the condition of safety sensor cables.
A
fl
ash
B
fl
ash
C
fl
ash
D
fl
ash
Monitoring error
Check safetysensor connections