12
Y
34
Y
Min 38
M
L
585
DA104
Frame depth
44
°
-55
°
Frame
depth
Pre-setting of the spring force
- After installation, ensure that the arm and door are properly
adjusted.
- Mount a door stop to the door open position so that wind will
not drive the door against the wall, resulting in damage.
- Tighten the holding screw.
7.3 Assembly of the operator and sliding arm DA149 to the closing side
Frame
depth
Arm distance
L
/mm
Minimum door
width
M
/mm
< 50
120
740
50-100
50
670
Y
Length of
extension piece
Mounting
of the arm
48
No extension piece M8x20 +
washer
58
10 mm (DA150/01) M8x30 +
washer
68
20 mm (DA150/02) M8x35 +
washer
Mounting of the operator: M6x14 and washer