11
Y
Min 21
320*
45
DA104
7.2 Assembly of the operator and standard arm DA147, DA148 to the closing side
Mounting of the operator: M6x14 and washer
11
°
-22
°
90
°
Pre-setting of the spring force
Frame
depth
42
Y
332
- After installation, ensure that the arm and door are properly adjusted.
- Mount a door stop to the door open position so that wind will not drive the
door against the wall, resulting in damage.
- Tighten the holding screw.
Frame depth
* If you need closing force according to
EN1154 class 6, use measurement 300 mm.
Y
Length of
extension piece
Mounting of
the arm
51 No extension
piece
M8x20 +
washer
61 10 mm
(DA150/01)
M8x30 +
washer
71 20 mm
(DA150/02)
M8x35 +
washer
Frame depth
DA147 0-150
mm
DA148 150-250
mm
Summary of Contents for DA461