| Configuring the Wallbox eMH2 –
Setting up an OCPP backend
38
Setting up an OCPP backend
The backend operator will provide all the information required for registering your Controller/Extender system, which
you then need to enter via the
Charge Point Administration
application.
NOTE
Supported network protocols
Communication between the Controller/Extender system and the backend can take place via the following net-
work protocols:
http:// (SOAP)
If communication is set up via SOAP, the local port and path for the endpoint (the Controller charging station)
must be specified.
ws:// (WebSocket) / wss:// (WebSocketSecure)
If communication is set up via WSS, you must check that the TLS certificates are correct and upload the
server certificate if necessary.
Proceed as follows to set up communication with the backend:
1
Click the
Connectivity > OCPP
tab.
y
In the
OCPP version
selection box, select the
OCPP version supported by the backend.
y
Under
Central system address (URL)
, enter
the Internet address of your backend provider.
y
In
Chargebox ID
, enter the OCPP name of the
Controller/Extender group.
y
Only for SOAP
:
»
Local port:
Enter a port address between
1000 and 10000 or use the default (
7890
).
»
Local path:
Enter the path of the local
endpoint here.
2
Confirm by clicking the
Save
button.
3
Only for WSS:
Click the
Connectivity > TLS
tab
and check the TLS versions and certificates shown
here.
y
Contact your network administrator if necessary.