Chapter 3
KG7-Lite/KG7/KG7-RAID
3-16
"
DataStrobe SlewRate (Fall):
Four options are available: Slowest
)
Slow
)
Fast
)
Fastest. The default setting is
Fastest
. This
item is used to directly program the fall time in all AGP data strobes.
DDR MA Configuration:
Two options are available: Auto or Manual. The default setting is
Auto
. When you choose “Manual” the
following four items will available for you to set. It is recommended this field be set to Auto in order to
avoid any errors in your system.
"
MA RiseEdge SlewRate:
Eight options are available: 0
)
1
)
2
)
3
)
4
)
5
)
6
)
7. The default setting is
5
. This item
can control the rising edge slew rate of the MA (
M
emory
A
ddress).
"
MA FallEdge SlewRate:
Eight options are available: 0
)
1
)
2
)
3
)
4
)
5
)
6
)
7. The default setting is
5
. This item
can control the falling edge slew rate of the MA (
M
emory
A
ddress).
"
MA P Drive Strength:
Four options are available: 0
)
1
)
2
)
3. The default setting is
3
. This item can control the P
transistor drive strength of the MA (
M
emory
A
ddress).
"
MA N Drive Strength:
Four options are available: 0
)
1
)
2
)
3. The default setting is
2
. This item can control the N
transistor drive strength of the MA (
M
emory
A
ddress).
DDR CMD Configuration:
Two options are available: Auto or Manual. The default setting is
Auto
. When you choose “Manual” the
following four items will available for you to set. It is recommended this field be set at Auto in order to
avoid any errors in your system.
"
CMD RiseEdge SlewRate (Command Rising Edge Slew Rate):
Eight options are available: 0
)
1
)
2
)
3
)
4
)
5
)
6
)
7. The default setting is
5
. This item
can control the rising edge slew rate of the RASB#, CASB#, WEB#, and CKEB# pins.
"
CMD FallEdge SlewRate (Command Falling Edge Slew Rate):
Eight options are available: 0
)
1
)
2
)
3
)
4
)
5
)
6
)
7. The default setting is
5
. This item
can control the falling edge slew rate of the RASB#, CASB#, WEB#, and CKEB# pins.
"
CMD P Drive Strength (Command P Driver Strength):
Four options are available: 0
)
1
)
2
)
3. The default setting is
3
. The item can control the P
transistor driver strength of the RASB#, CASB#, WEB#, and CKEB# pins.
"
CMD N Drive Strength (Command N Driver Strength):
Four options are available: 0
)
1
)
2
)
3. The default setting is
2
. The item can control the N
transistor driver strength of the RASB#, CASB#, WEB#, and CKEB# pins.
Summary of Contents for KG7
Page 2: ......
Page 10: ...Chapter 1 KG7 Lite KG7 KG7 RAID 1 6 ...
Page 28: ...Chapter 2 KG7 Lite KG7 KG7 RAID 2 18 ...
Page 64: ...Chapter 3 KG7 Lite KG7 KG7 RAID 3 36 ...
Page 78: ...6 4 Chapter 6 KG7 Lite KG7 KG7 RAID ...